GENEQ > Environment > Water Samplers

Portable Self-Contained Peristaltic Sampler
Model PSB

  

SELF-CONTAINED SYSTEM
The PSB is a completely self-contained portable peristaltic sampler, providing the most economical choice for basic, composite only, sampling needs. It comes complete with 10 ft. clear PVC hose, PVC strainer, 7 amp-hour battery, basic linear battery charger, controller with keypad, 2 gallon bottle, bottle full shut off switch, contact closure input, and resident time and flow based programming. The PSB is lightweight (22 lbs. with battery and empty bottle) and has a convenient carrying handle. When latched, it is rated NEMA4X/ NEMA 6. Power can be supplied through an internal or external 12-volt battery, a 110-220 VAC converter, or other 12VDC source.

RELIABLE PERISTALTIC PUMP
Model PSB samplers use a field proven1/4-inch ID peristaltic pump to collect samples. The pump is made of advanced thermoplastics to resist corrosion and promote longer tubing life. The pump rollers and tubing can be visually inspected without taking the pump apart. To reduce maintenance and replacement costs, the 1/4-inch ID pump uses Pharmed® long-life tubing. Unlike their samplers in its price range, the Model PSB sampler delivers consistent and accurate sample volumes by using liquid sensor technology coupled with sophisticated software.

VERSATILE CONTROLLER
The PSB sets the standard in the sampler industry for performance and price. Its microprocessor based controller offers advanced functionality and features such as data logging, review of settings and operating status, and a variety of flow and time modes.
With its step-by-step menu format, dedicated-button keypad, and large backlit LCD, the controller is simple to setup, even in the dark! Easy to understand prompts and "shortcut" keys save manpower and time by avoiding frustrating navigation through long, complicated menu structures.

COMPOSITE SAMPLING
The PSB is well suited for nontoxic applications. Dedicated to composite sampling, bottles are quickly and easily exchanged. The PSB is suitable for a wide variety of sampling applications in many locations, including manholes. Samples can be cooled by using ice packs or ice contained in a sealed bag.

BOTTLE OPTIONS
Extra bottles and lids are offered for quick and easy field replacement, enabling filled bottles to be sealed with clean lids for transport.

COMPREHENSIVE, FLEXILE PROGRAMMING
The Model PSB provides sampling programming that is unmatched in this price range. Its exceptional software is designed to be highly flexible and easy to use. The menu-driven system provides many programming features.

DURABLE DESIGN
The PSB sampler case has thick walls made of impact and corrosion-resistant structural resin. Also, watertight connectors are provided for external power, contact closure/pulse input, and the optional 4-20mA input. The case has a limited lifetime guarantee which is only one of the many reasons that make this well built sampler an excellent value for its price category.

SPECIFICATIONS
Overall Size W 20.5 in. (52.07 cm) x H 16.75 in. (42.55 cm) with carrying handle vertical x D 8.5 in. (21.59 cm)
Weight (dry) 18 lbs. (8.16 kg) with battery and empty sample bottle
Environmental Protection NEMA 4X/NEMA 6 structural resin housing around electromechanical components
Sample Cooling Contained ice or alternate ice (ice pack, gel pack, etc.)
Temperature Limits 32° to 122°F (0° to 50°C)
Sample Pump High-speed 1/4-inch ID peristaltic 12 VDC pump with impact and corrosion-resistant plastic pump body, and tri-roller mechanism
Pump Tubing/Tubing Life Pharmed® long-life tubing/typical 1000 hours life
Maximum Lift 28 ft. (8.2 m)
Transport Velocity 2 ft./sec. @ 5 ft. of lift (0.6 m/sec. @ 1.5 m of lift)
Sample Volume Programmed directly in 1 ml increments
Repeatability Typical ± 5 ml or ± 5% of the set sample volume (whichever is greater)
Liquid Sensor Continuity type or optional non-contacting ultrasonic
Membrane Keypad Hermetically sealed 24-key, multiple function keypad with 2-line by 20-character alphanumeric backlit LCD
Internal Clock Indicates real time with ± 1 minute per month accuracy
Internal Battery Backup 5-year internal lithium battery to maintain program logic, RAM memory, real-time clock, and date
Power Requirement
  • Standard: Internal 12-volt, 7 Amp-hour battery
  • Optional: External 12-volt, 17 Amp-hour battery or 110-220 VAC converter (for use without battery)
  • Input/Output (optional) Contact closure or 12 VDC pulsed input with or without 4-20mA input and/or RS-232 output in various combinations

    SPARE PARTS AND ACCESSORIES
  • Battery Chargers
  • External 110-220 VAC converter
  • Contact/pulse/analog input cables
  • RS-232 output 6 in. patch cable
  • Locking harness
  • Suspension harness
  • Tipping bucket rain gauge

  • ENGINEERING SPECIFICATIONS
    1. A Manning Model PSB series sampler is suitable for automatic collection and preservation of composite non-toxic liquid samples.
    2. The enclosure is made of structural resin with NEMA 4X/NEMA 6 ratings and ABS clasps
    3. All wetted parts have a minimum ID of 1/4-inch and is stainless steel or PVC (optional strainer), PVC (sampling hose), and Pharmed• (pump tubing).
    4. The sampler incorporates a high-speed 1/4-inch ID peristaltic pump with three rollers to increase tubing life and improve consistency of sample delivery. The pump body is constructed of corrosion and impact resistant polycarbonate. The pump mechanism is clear to enable visual inspection of rollers, pump spindle, and tubing. Samplers requiring removal of part or all of its pump housing for visual inspection will not be acceptable.
    5. Sample liquid is under forced flow at all times and does not pass through a metering chamber, valves or distribution plate. It is equipped with a liquid sensing system that calculates the flow rate of the liquid in the intake line every collection cycle.
    6. The sampler is capable of collecting composite samples. It is equipped with an overflow protection mechanism that automatically terminates any further sampling once it has been activated.
    7. Bottle-full condition is detected by using a float-type switch located in the bottle neck. It is easily removable for cleaning or replacement without using special tools.
    8. The sampler is capable of transport velocities of 2 ft./sec. through 1/4-inch tubing at a draw height of 5 feet using the 1/4-inch ID pump.
    9. An optional weighted sampling strainer of PVC or stainless steel is available.
    10. A hermetically sealed 24-button keypad and a 2-line by 20-character alphanumeric backlit LCD linked to a programmable CPU are used.
    11. The sampler is powered by:
      • The standard internal 12-volt, 7-amp hour lead acid battery. A power port is available to recharge the sampler battery or to extend sampler operation from an external 12 VDC power source such as an appropriate auxiliary battery or car cigarette lighter.
      • An optional external 12-volt, 17-amp hour lead acid battery, or,
      • An optional external 110-220 VAC converter.
    12. The sampler comes equipped with an external battery charger that can trickle charge the sampler battery while the sampler is operating. Use of a current-limiting dual-stage charger to prevent overcharging the sampler battery, diminishing its expected life is recommended. The charger is:
      • The standard basic, linear wall charger for 110 VAC operation that is not current limiting.
      • An optional current-limiting dual-stage charger for 110 VAC operation, or,
      • An optional current-limiting dual-stage charger for 220 VAC operation.
    13. No unique symbols or codes for programming or to indicate operating conditions are used. The software is menu driven, prompting input of requested information using the keypad. The display indicates each programming step. After entering data, the system automatically advances to the next programming step.
    14. A password feature to restrict access only to authorized persons is used.
    15. A sampling program is able to be delayed by entering the number of hours and minutes for the sampler to count down, or the number of contact closures to occur. The delay is independent of the sampling interval.
    16. The sampler purges the sample hose immediately prior to and following each sample. Purge duration is selectable.
    17. The sampler has the capability to rinse the sample hose with source liquid prior to each sample selected by the user.
    18. If a sample is not obtained on the first attempt, the sampler immediately retries to collect the sample. If the sample still cannot be collected, the sampler omits that sample and continues the sequence.
    19. The sampler is capable of manual sampling independent of a programmed sequence when initiated by a keystroke. It logs manual collections and is selectable to allow taking test samples:
      • Only when sampler is not running a program.
      • During a program but the test sample is not counted as a sample.
      • During a program and the test sample is counted as a sample.
    20. In the time mode, the interval between samples is adjustable (1-9999 min. in 1 min. increments). In the flow mode, the sampler accepts and totalizes contact closures (1-9999), a 12VDC pulsed input or a 4-20mA DC analog signal input for sampling at a user set point.
      • Sampler operating status is reviewed with minimal effort, and includes:
      • Program status
      • Current time
      • Time and date program started
      • Number of samples collected
      • Volume collected
      • Number of contact closures
      • Number off-line blockages
      • Minutes or flow signals remaining to the next sample
      • Number of samples remaining
      • Volume remaining
      • Time to override

    All program settings are also reviewed in addition to seeing the review of the completed program. The sampler has diagnostics for
    RAM, ROM, pump, and distributor.