GENEQ > Environment > Air Samplers
| Personal Sampling Pumps |
| Model SidePak SP330 & SP350 |
| FEATURES |
|
Smart Battery Management System |
|
|
Multiple Battery Options |
|
|
User keypad programming |
|
| SPECIFICATIONS | ||
|
SP330
|
SP350
|
|
| Flow Range | ||
| Constant Flow |
500 to 3,000 cc/min
|
500 to 4,000 cc/min
|
| Constant Pressure |
20 to 800 cc/min (requires low flow
adapter)
|
|
| Flow Control | ||
| Back EMF |
±5% of constant flow setpoint
|
|
| Flow Performance | ||
| Flow vs. Max Vacuum Pressure |
|
|
| Flow Fault |
If flow is blocked and drops by more
than 3% for more than 20 seconds, the pump stops and retains all sample
data. Auto-restart is attempted after 40 seconds up to 10 times.
|
|
| Flow Indicator |
Adjust Flow Menu Screen, range 0.0
to 99.9% for both
|
|
| Inlet Pulsation Ratio |
8%@ 2.0 lpm w/GF filter
|
9%@ 2.0 lpm w/GF filter
|
| User Adjustable |
Sample Run Time
Values: Flow Setpoint, Delayed Start, Key Pad Lock |
|
| Recorded Values Temperature Range: Total Sample Time | ||
| Operating Range |
0 to 45°C (32 to 112°F)
|
|
| Storage Range |
-20 to 60°C (-4 to 140°F)
|
|
| Physical | ||
| External Dimensions |
With 801724 battery: 106 mm x 92
mm x 70 mm (4.2 in. x3.7 in. x2.8 in.)
|
|
|
With 801722 or 801708 battery: 130
mm x 92 mm x 70 mm
(5.1 in. x 3.7 in. x 2.8 in.) |
||
| Weight |
|
|
| Display |
2 line x 12 character LCD
|
|
| Tripod Socket |
1/420 female thread
|
|
| Power Supply (P/N 2613210) | ||
| Input Voltage Range |
100 to 240 VAC, 50 to 60 Hz
|
|
| Output Voltage |
9 VDC @ 1.0 A
|
|
| Maintenance | ||
| Factory clean and test |
Recommended annually
|
|
| User flow calibrations |
Before and after each use
|
|
| Approvals | ||
| TSI Battery Pack P/Ns |
801722 or 801724
|
|
| Intrinsic Safety |
INTRINSICALLY SAFE CSA
|
|
| Rating Information |
|
|
| Immunity |
EN61326-1:1997 + A11998 Clause 6
|
|
| Emissions |
EN61326:1997 + Amendment A1:1998
|
|
| BATTERY INFORMATION | ||
|
Battery Option
|
Charge Time*
|
Intrinsically Safe
|
| 1650 mAH NiMH Pack (P/N 801724) |
3.5 Hours
|
Yes**
|
| 2700 mAH NiMH Pack (P/N 801722) |
5.5 Hours
|
Yes**
|
| 6-Cell AA-size Pack (P/N 801708) |
NA
|
No
|
| * Of a fully depleted battery | ||
| ** All dust plugs and dust gaskets must be installed | ||
| BATTERY LEVEL INDICATOR |
The Smart Battery Management System
utilizes a built-in gauge in the SIDEPAK battery packs. The
gauge monitors battery capacity and calculates run time information by
dividing capacity of the battery (mAH) by the instantaneous current consumed
by the instrument (mA). This calculation is correct for current operating
conditions and can change due to current (mA) consumption or changes in
battery capacity. |
| TYPICAL COLLECTION MEDIA BACK PRESSURES |
![]() |
| BATTERY LIFE PERFORMANCE (estimated hours) |
![]() |
| *** Using Energizer AA-size, E91 alkaline batteries |