| The new portable gauge was especially
designed for non-destructive
coating thickness measurement of
paint, varnish, plastics and other
insulation coatings applied on wood,
plastics, glass, ceramics etc. as well as
for polymer layers on metals. As a
special feature, the gauge offers the
possibility to measure the total thickness
as well as the individual layers
of a multi-layer system in only one
measuring process. The robust gauge
is appropriate for use in the laboratory,
in production and on site. |
|
When the probe is placed on the
coated surface, it sends sound pulses
which penetrate the coating through
to the base material. Provided the
coatings and the substrate possess
different acoustic properties, these
pulses are reflected by the different
surfaces and transmitted to the transducer
in the probe. The various time
intervals are measured and calculated
by a microprocessor to give
individual and total coating thickness.
The time to obtain a reading
is approx. two seconds or less. If the
portable MiniPrint printer is connected
all readings and statistical
data can be printed out in individual
memories and batches. |
- Gauge conforming to DIN EN
ISO 2808, ASTM D6132, with
probe, cable and rechargeable
batteries
- Mains unit with Euro / US adapter
- Operating instructions
- Plastic case
- Coupling liquid, 100 g
- Software Qsoft
- RS 232 connection cable
- Single layer control standard
|
- Portable printer MiniPrint
- Rubber protection case with mounting device (neck cord optional)
- Belt case set – two cases of different size for gauge and accessories
- Carrying case for gauge and printer MiniPrint
|
| Field of applications and measuring ranges: |
| Single layers: |
10 μm…500 μm |
| Multi-layers: |
max 500 μm total coating thickness |
| Wall thickness of metals: |
0.1…8 mm |
| Wall thickness of plastics: |
0.2…3 mm |
| Resolution: |
1 μm |
Measuring uncertainty < 100 μm Measuring uncertainty > 100 μm |
± (2 μm + 3 %*) ± (2 μm + 2 %*) (*of reading) |
| Memory capacity: |
max. 10,000 measuring values
in max. 500 batches |
| Statistical evaluation: |
n, x- , s, kvar, max, min,
with time and date of print-out and reading |
| Limit setting: |
with optical and acoustic warning when limits are exceeded |
| Interface: |
RS 232 C for MiniPrint data printer |
| Power supply: |
2,4 V akkupack:
2 x 1,2 V AA NiMH or NiCd (approx. 2,500 measurements) |
| Charger: |
90 V~ to 264 V (charging time: 4 hours) |
| Dimensions/weight: |
Gauge: 150 mm x 82 mm x 35 mm/150 g, Probe 30 mm x 45 mm dia. |
| Ambient temperature: |
–15 °C…+55 °C |