Radiation Alert
Model URSA-II
![]() |
| FEATURES |
|
URSA-II has everything you would expect in a full-featured
MCA and has been greatly improved over the original URSA by taking into
account requests and comments from our current customers. It can be used
with practically any radiation detector you currently have or want to purchase
and can extract any data your detector can supply!
| APPLICATIONS |
|
The all-new, fully quantitative, WindowsTM-based URSA-II
software package has been designed for ease of use in a 32-bit WindowsTM
environment. Software includes MCAce-II software to run the
URSA-II using a Pocket PC (Jornada, iPAQ, etc.) running WindowsCE. Can be
installed on as many computers as you like, with no restrictions and free
updates.
| SOFTWARE INCLUDES |
|
| MINIMUM SYSTEM REQUIREMENTS |
| Windows 95TM or higher. Connects to controlling computer using a standard RS232 serial port, or USB using RS232-to-USB adapter. Supports both high and normal data rates using USB, although all computers may not be capable of handling the dataflow. |
| SPECIFICATIONS |
| 4096-channels, can also be configured for 256, 512, 1024, or 2048 channels. Internal bias voltage supply provides positive high voltage from 0 to 2000V at up to 0.5mA. Adjustable shaping time, 0.25 to 10 µs. Achive wide gain range from x1 to x250 by utilizing coarse and fine gain controls. |
| Detector Types |
| The URSA-II has been demonstrated to work with the following types of detectors |
|
| Detector Connections |
| Two detector inputs. One standard series C connector for detectors where the signal is joined with the high voltage supply. The other is for detectors having separate connections for high voltage (SHV connector) and signal (BNC connector). Active detector input is selected via software, and can be negative, positive, or pre-shaped (positive) signal. |
| External Connections |
| External connector provides +5V, +12V, and -12V for external preamplifiers if needed and two logic signals for notifying external devices of alarm conditions. |
| Switches |
| Power On/Off, and Fast/Slow charging rates. (Internal switch located in the battery compartment suppresses battery-charging circuitry when non-rechargeable batteries are being used.) |
| LEDs Indicators |
| On/Off, External power availability, and fast charge activation |
| Power |
| External 110V or 220V to 12VDC power supply delivering 1.25 mA continous current (please specify), six AA NiMH rechargeable batteries (included) with internal recharging , or six standard alkaline "AA" batteries. External 12VDC power jack allows instrument to plug into vehicle. "Fast Charge" of NiMH batteries can also be selected. |
| Size |
| 6.186 long x 3.558 wide x 1.718 deep. |
| Weight |
| 13.8 oz. without batteries. |