Geneq > Teaching Equipment > Measure & Regulation

Regulation of a Heat Exchanger
Model RCT 101


  • The unit is delivered complete with instrumentation, technical documentation, and instructions.
  • Designed and manufactured to industrial standards.
  • This unit is designed for various levels and fields of study
  • Inlets and outlets are connected using Ø 4 mm female safety sockets -
    Options:
    – Interface and software for PC
    – Utilities module
  • It is possible to connect this unit in series with another regulation unit and to use the valve as a main control.
UTILITIES
Electricity : 230 Vac – single-phase Water : 10 L/min – 3 bar (44 psi) Compressed air : 6 bar (90 psi) maximum

DIMENSIONS
Length : 780 mm Width : 570 mm Height : 590 mm Weight : 50 kg

Applications
  • Technical data for the elements of a regulation loop
  • Sensor – regulator – actuator – perturbing element
  • PID or self-adaptive
  • Configuration of the regulator
  • Characteristic curves (temperature, valve opening, time of response, etc…)
  • Study including advantages of regulation in cascade
    – Co-run
    – Back-run
    – Laminary/turbulent flows

Specifications
Temperature probes
Pt 100 Ω – class A
Stainless steel 304 L

Temperature indicator
Display 0.1°C
Recopy of the measure (4-20 mA) on jack - Ø 4 mm

Thermoregulator group
Capacity : 5 litres
Adjustment from +20°C to +100°C
Power 1600 W
Incorporated regulation at ±0.5°C
Circulation pump

Exchanger
Monotubular – stainless steel
External tube covered by a thermal insulator
Hot water into the internal tube
Cold water into the external tube
Quick and interchangeable connections on the cold-water network for the lead through in co or back-run

Electromagnetic flow meter
PFA covering, stainless steel electrodes
Local display, outlet 4-20 mA

Regulation valve
Stainless steel body
Variable Cv
Pneumatic positioner and actuator

PID type regulator with microprocessor
Accuracy class 0.2
Configurable scale range
Continue, logical, relay outlet
– Proportional band from 0.5 to 1000%
– Integral action time from 0.1 to 100 min
– Derived action time from 0.01 to 10 min
Self-adaptive: the PID parameters are calculated by the regulator for an optimized regulation
Numerical outlet : MODBUS RS 232
One of the regulators has an external control inlet for regulation in cascade

Variable section flow meter
Rotameter : accuracy ±3% of the full scale

Perturbation valves - 1/4 turn
On hot and cold circuit

1/4-turn valves for connection in series