GENEQ > Environment > Water Samplers
| Refrigerated Wastewater Sampler |
| Model WS700R |
| Portable, Rugged, and Refrigerated Samplers |
| Features |
| • Ideal for refrigerated wastewater,
industrial and environmental sampling • Simple to operate – no programming required • Rugged construction for harsh environments • Meets federal, state and local wastewater regulations • Timed and external flow pulsed composite samples • Adjustable and repeatable sample volume • Peristaltic pump prevents sample contamination |
|
Refrigerated Wastewater
Samplers Product Description |
Global Water's WS700R Refrigerated
Wastewater Samplers combine all the features you need to meet a wide variety
of water sampling requirements, including those for stormwater, industrial
discharge, water and wastewater treatment, waste collection systems, and
rivers and streams. The WS700R Refrigerated Wastewater Sampler's state of the art water sampler controller gives you complete control over your water sampling process. With the water sample size control, you can take individual time-weighted composite samples or full-bottle discrete grab samples in a 2 gallon sample bottle. The water sample interval control allows you set the time between individual refrigerated composite samples or enable the external trigger mode for flow proportional sampling. A start delay timer allows you to start multiple refrigerated water samplers in the field at the same time, or to delay drawing a water sample after a triggering event so that your water sample better represents the water source. An automatic 15 second backflush cycle clears any debris from the strainer and empties the water from the hose so the next refrigerated composite sample is not contaminated. The WS700R Refrigerated Wastewater Samplers are easy to set up in the field. The refrigerated wastewater samplers rugged rainproof enclosure can be padlocked and/or chained to prevent tampering. The refrigerated wastewater samplers are enclosed in a relatively small case that can be easily hidden or camouflaged to prevent vandalism. The refrigerated wastewater sampler's is lightweight enough that even with a full sample bottle it can be suspended in a manhole for wastewater or stormwater sampling. The WS700R Refrigerated Wastewater Samplers come with a 2-gallon polyethylene sample bottle for collecting refrigerated composite samples, a peristaltic sampling pump, a circuit board controller, and a rechargeable gel cell battery. Also provided is a sample pickup hose and a battery charger. Everything you need is provided for a successful wastewater management or environmental monitoring program. |
|
Overflow Protection
|
The refrigerated wastewater sampler's
sample bottle is equipped with a float switch that automatically turns
off the peristaltic sampling pump if the water bottle becomes full. |
|
Sample Size
|
The user can adjust the refrigerated
wastewater sampler's sample size to one of 15 composite sample sizes from
50ml to 2 liters plus a full bottle discrete setting and the refrigerated
wastewater sampler's sample interval to one of 15 time settings from 5
min. to 12 hours plus an external trigger mode setting for flow proportional
sampling. |
|
Flow Proportional
Sampling |
| An external pulse-type flow meter can control the water sample interval for true flow proportional sampling. Global Water's Open Channel Flow Monitor has a flow-proportional output signal for triggering the WS700R refrigerated wastewater samplers. If you already have a flow meter but it has a 4-20mA output, please look at the related products section of the Refrigerated Water Samplers Options & Prices section. |
| Refrigerated Wastewater Samplers Specifications |
| Operating Temperature: 0° to +70°C Size of unit: 27"H X 20"W X 20"D Weight: 40lb (Shipping Weight 42lb) Materials: Enclosure: Expanded UV protected PVC Bottle: 2.5 gallon Polyethylene Pickup Hose: 15' reinforced PVC 1/4" ID polyethylene flexible tubing section with intake strainer Pump Tubing: Norprene 1/4" ID, 7/16” OD Sample Pump: Flow Rate: 1000 ml per minute at a 4 foot head Type: Peristaltic Maximum Lift: ~20 feet Power: Internal 12V Rechargable Battery with AC 120 VAC adapter/charger Standby: 3 months while still retaining enough power to run the pump to capacity Start Delay: 16 time settings from 0 to 12 hours Composite Interval: 15 time settings from 5 min. to 12 hours plus an External Trigger mode setting Sample Size: 15 composite sample sizes from 50ml to 2 liters plus a Full Bottle discrete setting (Approximate sizes at 4 foot head) External Trigger Input: 250mS minimum pulse width Switch closure or 4-24VDC Pulse Output: 5VDC one-second pulse 1000ohm output impedance Bottle Switch Input: Switch closure Input Floating read switch in bottle Rain and Water Sensors: Optional moisture sensors or switch closure inputs Internal Fuse: 10A Slow-Blow |
| Refrigerated Wastewater Samplers Options | ||
| WS700R Refrigerated Wastewater Sampler | ||
| Refrigerated samplers for composite samples of stormwater or industrial discharge flows. | ||
| 01-342 Quick Release Pump Head | ||
Includes
CA0400 Rain Sensor, CA0500 Flow Sensor and RG333 Auto-drain Rain Gauge. ![]() |
||
| WSSWK Stormwater Kit | ||
Includes CA0400
Rain Sensor, CA0500 Flow Sensor and RG333 Auto-drain Rain Gauge.![]() |
||
| FN0000 Smart Charger | ||
| Maintain constant battery voltage and increase battery life. | ||
| REPLACEMENT PARTS | ||
| 00-010 00-546 CA0300 CA0400 CA0500 00-744 CD0300 01-283 RG333 |
12V 5AH Rechargable
Battery Reinforced PVC Pickup Hose Pickup Strainer Rain Sensor Flow Sensor Peristaltic Pump Tubing Float Switch 2.5 Gallon Plastic Bottle Auto-Drain Rain Gauge |
|
| RELATED PRODUCTS | ||
| WS700 Composite/Discrete Water Sampler | ||
| Single pump stormwater or wastewater sampler. | ||
| WS750 Stormwater/Wastewater Sampler | ||
| Dual pump stormwater or wastewater sampler. | ||
| WS500 10 Gallon Composite Sampler | ||
| WS700-PCO Portable Cooler Composite Sampler | ||
| Mobile sampler
with attached cooling unit . ![]() |
||
| WS700-IBO Ice Bag Composite Sampler | ||
Portable composite
sampler with internal ice bag. One gallon sample bottle included.
|
||
| RG750/RG755
4-20mA to Pulse Converter Module |
||
| This
module is for use with flow monitors that produce a 4-20mA output.
There are two versions available, one that pulses every 15 minutes at
20mA (RG750) and one that pulses every 30 minutes at 20mA (RG755).
Please specify the unit conversion that best suits your application at
the time of order. |
||
| AD200-1 Voice Alarm Autodialers | ||
| Voice alarm autodialers includes one inputs and four phone/pager numbers. | ||
| 3 FT Long Handled Dipper | ||
| Swing Sampler w/Pole & Bottle | ||
| Sludge Judge, 15 FT | ||
| GL500-7-2 Multichannel Data Logger | ||
| Features
7 analog channels and 2 pulse channels, USB and serial communication port,
and includes software and cables. Requires an external 12 VDC power
source. |
||
GL500-2-1
Datalogger |
||
| Specify
Serial or USB version when ordering. Features 2 analog channels
and 1 pulse channel. Includes two internal 9V batteries, Windows-based
Global Water Datalogger Software, and PDA software for the CE operating
system. |
||
WQ900
Water Pollution Testing Kit |
||
FSS
Flow Sampling System |
||
| A
unique combination of instruments that makes monitoring, sampling, and
recording stormwater or industrial discharge water flows easy. |
||
WQS
Water Quality Sampling System |
||
| A
unique combination of instruments that allows for monitoring, sampling,
and recording of water flows that exceed a water quality parameter such
as turbidity, pH, conductivity, ect.
|
||
SIT60
Satellite Internet Telemetry |
||
| Replace
the datalogger on your composite sampler with a telemetry system that
pages you or alerts you via text messaging that your sampler took a sample.
|
||