GENEQ > Environment > Spectrophotometers

Smart Spectrophotometer
Model 2000

The SMART Spectro is a portable spectrophotometer that is easier to use and more accurate than anything in its price range. With automatic wavelength selection, pre-programmed tests, and superior performance - this is the best spectrophotometer for the money!

Over 40 pre-programmed tests included, and 25 user calibrations can be entered into the memory. The user can also customize sequences for frequently run tests.


ADVANCE FEATURES
  • A wider wavelength range
  • Menu-driven display
  • Pre-programmed tests with 25 user tests
  • Automatic wavelength selection
  • Unique optical design system using a 1200 lines/mm grating
  • Greater accuracy, higher resolution
  • The SMART Spectro is supplied with 6 sample tubes (25mm round), 2 sample cell holders (25mm round and COD, 10 mm cuvettes), AC adapter, battery charger, instruction manual including test procedures, and quick start guides.

Pre-Programmed Tests with many more to come!

Aluminum
0-0.3 ppm
Ammonia-Noitrogen LR
0-1.0 ppm
Ammonia-Nitrogen HR
0-4.0 ppm
Bromine LR
0-9.0 ppm
Chlorine
0-4.0 ppm
Chlorine Dioxide
0-7.0 ppm
Chromium
0-1.0 ppm
COD Standard
20-900mg/L
COD LR
5-150mg/L
COD HR
100-4500mg/L
Copper (BCA) LR
0-3.5 ppm
Copper (DDC)
0-6 ppm
Cyanide
0-0.5 ppm
Cyanuric Acid
0-200 ppm
Dissolved Oxygen
0-12.5 ppm
Fluoride
0-2.0 ppm
Hydrazine
0-0.75 ppm
Hydrogen Peroxide LR
0-1.5 ppm
Iodine
0-14 ppm
Iron (Bipyridyl)
0-6 ppm
Iron (1, 10-Phenantroline)
0-4.5 ppm
Manganese LR
0-0.50 ppm
Molybdenum HR
0-15 ppm
Nickel
0-10.0 ppm
Nitrate-Nitrogen HR
0-3.0 ppm
Nitrite-Nitrogen LR
0-0.8 ppm
Ozone LR
0-0.4 ppm
pH (CPR)
5-7
pH (PR)
6.6-8.4
pH (TB)
8-9.5
Phenol
0-6.0 ppm
Phosphate LR
0-3.0 ppm
Phosphate HR
0-70 ppm
Potassium
0-10 ppm
Silica LR
0-2.5 ppm
Silica LR
0-50 ppm
Sulfate HR
6-100 ppm
Sulfite LR
0-3.0 ppm
Tannin
0-10 ppm
Turbidity
0-400 FTU
Zinc LR
0-3.0 ppm

SPECIFICATIONS
Wavelength range 350-1000 nm
Wavelength accuracy ±2 nm
Wavelength resolution 1 nm
Wavelength bandwidth 5 nm (max)
Photometric range 0-125%T, -0.1-2.5A
Photometric accuracy ±0.005A
Photometric Noise <0.001A at 0A, <0.002A at 2A
Photometric Drift ±0.002A/hr @ 500 nm
Photometric Stary Light <0.5%T
Dispersive device Grating - based system
Optical Mount Modified Ebert
Grating 1200 grooves/mm ruled grating
Light Source Quartz halogen
Bulb life 1000 hours minimum
Sample Chambers 25mm round cell, 10 mm quare cuvette UDV, COD, flow-through (optional)
Detector Silicon photodiode
Temperature range 0-40°C
Mode Conc, %T, ABS
Pre-Programmed Tests Yes
Wavelength selection Automatic
User Tests Yes, up to 25 can be entered and edited
Datalogging Yes, RS-232
Diagnostics Yes
Power 115/230 volt or baterry pack (rechargeable)
Weight 4.65 kgs (10.3 lbs)
Size (WxDxH) 35 cm x 28 cm x 17 cm
CE Mark Yes

CAT. NO. DESCRIPTION
LAM2000-00 Smart Spectro Spectrophotometer includes 6 sample cells (25 mm round), 2 ssample cell holders (25 mm tound and COD, 10 mm cuvette), power supply, battery charger, manual
LAM2000-CS Carrying case
LAM2000-BP Battery Pack with holder (rechargeable)