A lightweight Handheld meter for measuring
the chlorophyll content of leaves without causing damage to plants. The
SPAD-502 is a compact meter designed to help users improve crop quality
and increase crop yeild by providing an indication of the amount of chlorophyll
present in plant leaves. The amount of chlorophyll content of plant leaves
is related to the condition of the plant, and thus can be used to determine
when additional fertilizer is necessary. By optimizing nutrient conditions,
healthier plants can be grown, resulting in a larger crop yeild of higher
quality. |
| FEATURES |
|
| APPLICATIONS |
Checking the nutritional condition
of plants The chlorophyll present in the plant is closely related to the nutritional condition of the plant. For a particular plant species, a higher SPAD value indicates a healthier plant. |
Determining when additional fertilizer
is necessary A decrease in the SPAD value indicates a decrease in the chlorophyll content and nitrogen concentration. This decrease may be due to a lack of nitrogen available in the soil. This problem can be solved by adding fertilizer to the soil. For example, it was determined from past experience that for Sasanishiki rice plants a SPAD value of 35 or above was desirable to produce target yield of 600kg/10a. During the differentiation and formation of ears, a period of rapid plant development, the SPAD value fell to between 29 and 32, indicating thant additional fertilizer was necessary. |
| SPECIFICATIONS | |
| Type | Handheld meter for measuring chlorophyll using optical density difference at two wavelengths |
| Measurement Sample | Crop leaves |
| Measurement System | Optical density difference at two wavelengths |
| Measurement Area | 2 x 3 mm |
| Light Source | 2 LED's (light emitting diodes) |
| Receptor | 1 SPD (sillicon photodiode) |
| Display | Measurement data: 3 digits LCD with decimal point Data number: 2 digits with LCD |
| Data Memory | Space for 30 data sets |
| Controls | Power switch, average key, all data delete key, one data delete key, and data recall key |
| Power Source | 2 AA size alkaline manganese (1.5V) batteries |
| Battery Life | More than 20,000 measurements |
| Min. Interval Between Measurements | Less than 2 seconds |
| Accuracy | With in +/-1.0 SPAD unit (at room conditions, SPAD value between 0 and 50) |
| Repeatability | Within +/-0.3 SPAD units (SPAD value between 0 and 50) |
| Reproducibility | Within +/- 0.5 SPAD units (SPAD value between 0 and 50) |
| Temp. Drift | Less than +/-0.4 SPAD units/°C |
| Temp. Range | Operation: 0 to 50°C Storage: -20 to +55°C |
| Dimensions | 14 x 78 x 49 mm (6-7/16 x 3-1/16 x 1-15/16 in.) |
| Weight | 225g not including batteries |
| Other | Warning buzzer User calibration function |
| CAT. NO. | DESCRIPTION |
| MISPAD502- | chlorophyll meter SPAD-502 |