Geneq > Meteorology > Data Loggers - Miniature

Seven-Channel Temperature Data Logger
Model SmartReader 6


The SmartReader 6 data logger is ideal for those applications that require multi-site temperature monitoring of extremely high temperatures or wide temperature ranges. The logger has one internal channel for measuring ambient temperature and six external channels for use with ACR thermocouple wire or any J, K, S or T type thermocouple.

Applications
Monitoring performance of gas-fired heating equipment, verifying concrete curing temperatures, process verification, etc.

General Specifications
Size 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 8-bit (1 part in 256)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows XP SP3, Windows Vista SP2& Windows 7 (32 bit & 64 bit)
Memory Size 32 KB (capable of storing up to 32,767 readings)
Sampling Rates User selectable rates from 8 seconds to 5 days in 4-second increments
Number of Channels Seven (One internal thermistor for cold-junction compensation and six external channels for thermocouple inputs)

Sensor Specifications
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C
(-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F)
Temperature Ranges and Resolution:
SR-006N (Narrow Range Version) Range Resolution
J Type thermocouple: -20°C to 190°C (0°F to 370°F) 1.4°C (2.5°F)
K Type thermocouple: -25°C to 230°C (-10°F to 440°F) 1.7°C (3°F)
S Type thermocouple: 0°C to 960°C (32°F to 1750°F) 7°C (12.6°F)
T Type thermocouple: -35°C to 200°C (-30°F to 390°F) 1.7°C (3°F)
SR-006W (Wide Range Version) Range Resolution
J Type thermocouple: -50°C to 600°C (-55°F to 1100°F) 5°C (9°F)
K Type thermocouple: -100°C to 900°C (-145°F to 1650°F) 6.7°C (12°F)
S Type thermocouple: 0°C to 1760°C (32°F to 3200°F) 23°C (41.5°F)
T Type thermocouple: -200°C to 400°C (-325°F to 750°F) 6.7°C (12°F)
Accuracy ±1% of range + resolution

Ordering Information
Item Cat No.
SR-006N (SmartReader 6 - Narrow Range Version) 01-0029
SR-006W (SmartReader 6 - Wide Range Version) 01-0030