Modèle SmartReader 7


The SmartReader 7 data logger is a versatile data logger that can monitor and record a variety of different process signals including the popular 4-20mA and 0-5V. With its seven input channels, the logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters.

Applications
Monitoring wind speed, flow, tank level, pressure, current, voltage, power, SCADA troubleshooting, etc.

General Specifications
Size 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 8-bit (1 part in 256)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows XP SP3, Windows Vista SP2& Windows 7 (32 bit & 64 bit)
Memory Size 32 KB (capable of storing up to 32,767 readings)
Sampling Rates User selectable rates from 8 seconds to 5 days in 4-second increments
Number of Channels Eight (One for the internal temperature sensor and seven external channels for analog voltage and current loop signals.)

Sensor Specifications
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.4°C (0.7°F) @ 25°C; better than 1°C (1.8°F) between -25°C and 70°C
(-13°F and 158°F); better than 2.0°C (3.6°F) between -40°C and -25°C (-40°F and -13°F)
Standard Model (SR-007) Other Models
Input Range* Input Range*
0 to 10V DC (1 channel) All external channels: 0 to 10V DC (SR-007-0-10V)
0 to 200mV DC (1 channel) All external channels: 0 to 25mA (SR-007-25mA)
0 to 25mA DC (2 channels)  
Maximum Protection Voltage channels: ± 40V (reverse-polarity protected)
Current channels: ± 70mA (reverse-polarity protected)
Input Impedance >1M Ohm (200mV channel)
>1M Ohm (0 to 2.5V channel)
20K Ohm (0 to 5V channel)
40.9K Ohm (0 to 10V channel)
100 Ohm (0 to 25mA channel)
Accuracy ±1% of full scale
*Transducer restrictions: The use of a single power supply is recommended to avoid ground loops or use loop isolators.

Ordering Information
Item Cat No.
SR-007 01-0031
SR-007-10V 01-0041
SR-007-25mA 01-0032