Geneq > Meteorology > Data Loggers - Miniature

Four-Channel Temperature and Relative Humidity Data Logger
Model SmartReader Plus 2


The SmartReader Plus 2 is a self-contained data logger that can monitor and record temperature and relative humidity right out of the box. The on-board RH sensor is temperature compensated, permitting reliable, worry free RH readings. For remote sensing of temperature and RH, simply attach ACR’s temperature/RH probe, or for remote temperature sensing, attach up to two thermistor probes.

Applications
Monitoring the transportation or storage conditions of perishable and/or pharmaceutical goods, tracking “air quality”, HVAC system testing and balancing, etc.

General Specifications
Size 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out)*, Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows XP SP3, Windows Vista SP2& Windows 7 (32 bit & 64 bit)
Memory Size 128 KB (capable of storing up to 87,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Four (one for the internal temperature sensor, one for the internal RH sensor and two for remote measurements of temperature and RH [with ACR’s EH-020A

Sensor Specifications
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)
Internal Relative Humidity Sensor
Type Capactive thin polymer film
Range 0 to 95% RH (non-condensing)
Accuracy ±3% RH from 10 to 90% RH (-20°C to 40°C [-4°F to 104°F])
Resolution Better than 0.04% RH between 25% and 60% RH @ 25°C (77°F)

Ordering Information
Item Cat No.
S RP-002-128K (SmartReader Plus 2) 01-0113