Geneq > Meteorology > Data Loggers - Miniature

Eight-Channel AC Current, Voltage and Temperature Data Logger
Model SmartReader Plus 3


The SmartReader Plus 3 easily and accurately records AC current and voltage. Simply connect the logger to ACR’s current probes (which are clamped around the power leads) and voltage transducer and begin recording. From this data, you can also determine energy consumption (kWh) with TrendReader® 2 Software.

Applications
Determining energy consumption, monitoring 3-phase voltage and current, start-up or long-term load analysis, demand side management, electric motor maintenance scheduling, etc.

General Specifications
Size 107mm x 74mm x 22mm (4.2” x 2.9” x 0.9”)
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium, 1 Amp-Hour
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out)*, Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows XP SP3, Windows Vista SP2& Windows 7 (32 bit & 64 bit)
Memory Size
(3 models available)
32 KB (capable of storing up to 21,500 readings)
128KB (capable of storing up to 87,000 readings)
1.5MB (capable of storing up to 1,048,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours (BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Eight (one for internal temperature, four for AC current and three 0-5V DC inputs for use with ACR’s voltage transducer to monitor 3-phase voltage)

Sensor Specifications
Internal Temperature Sensor
Type NTC Thermistor - 10,000 Ohm @ 25°C (77°F)
Range -40°C to 70°C (-40°F to 158°F)
Accuracy ±0.2°C over the range of 0°C to 70°C (± 0.3°F over the range of 32°F to 158°F)
Resolution 0.03°C (0.05°F) @ 25°C; better than 0.07°C (0.12°F) between -25°C and 70°C (-13°F and 158°F); better than 0.13°C (0.23°F) between -40°C and -25°C (-40°F and -13°F)
Current Sensors Range Cat. No.
A60FL (60 Hz) 5, 25, 100, 250 Amps 35-0004
A65FL (50 Hz) 5, 25, 100, 250 Amps 35-0006
A70FL (60 Hz) 10, 50, 250, 500 Amps 35-0005
A75FL (50 Hz) 10, 50, 250, 500 Amps 35-0007
Nominal Voltage Ranges: Accuracy:
120V (1 phase, 60 Hz) Current channels: ±3.0% of full scale above 10% of range
480V 3 phase, 60Hz) Voltage channels: ±0.5% of full scale

Ordering Information
Item Cat No.
SRP-003 01-0010
SRP-003-1.5M 01-0143