| SymphoniePLUS 15-channel datalogger |
![]() |
![]() |
SymphoniePLUS is the core of NRG Systems’ complete system approach: tower, logger and sensors all designed to work together specifically for measuring the wind’s energy. |
|
| Features |
|
| Specifications |
| Description | |
| Instrument type | 15 channel internet-enabled wind energy data logger |
| Applications | • wind resource assessment |
| Sensor compatibility - counter channels | • NRG #40C anemometer • opto anemometer • reed switch anemometer • rain gauge |
| Sensor compatibility - analog channels | • NRG 200P direction vane • NRG 110S temperature • Li-Cor 200SA pyranometer • NRG BP-20 absolute pressure (requires optional iPack power) • RH-5 relative humidity (requires optional iPack power) |
| Counter channels | Channels 1-6 and 13-15 are counter inputs: • channels 1-3 and 13-15 are pre-programmed for NRG #40C anemometers or compatible sensors • channels 4-6 use counter Signal Conditioning Modules (SCMs) to configure the channels for other sensors |
| Analog channels | Channels 7-12 are analog inputs: • channels 7 and 8 are dedicated for NRG 200P direction vane • channels 9-12 use analog Signal Conditioning Modules (SCMs) to configure the channels for other sensors |
| Data Collection | |
| Sampling interval | 2 seconds |
| Averaging interval | 10 minute, fixed |
| Real time clock | internal battery-backed |
| Storage medium | 32 MB MultiMedia Card (MMC), non-volatile FLASH |
| Maximum data storage | 664 days |
| Parameters recorded for each channel | • each 10 minute interval is time/date-stamped • average • standard deviation • min* • max* *min and max not used for wind direction vanes |
| File format | • Windows compatible • (1) 14 KB binary file per day • header includes site, serial number and sensor information |
| Software | Symphonie Data Retriever for Windows (included) • scales raw data • creates measurement database for each site • creates basic reports • maintains site and sensor information • configures iPacks |
| Reader | Windows compatible MMC reader accesses data stored on MMC |
| Data delivery | • MMC cards, and/or internet email via optional iPack: GSM, CDMA (Verizon or Telus) and Iridium Satellite |
| Resolution | |
| Analog measurement resolution | 0.1% of full scale (1024 counts) |
| Counter average stored resolution | 0.1% of the value stored |
| Analog average stored resolution | 0.1% of the value stored |
| Min / Max stored resolution | 0.4% of the value stored |
| Standard deviation stored resolution | 4% of the value stored |
| Configuration | |
| User interface | • Liquid Crystal Display (LCD) 4 x 20 characters • 16 key pad (6 navigation keys plus numeric/phone pad) with audible feedback |
| Configurable parameters | • clock • time zone • site number • display scaling (defaults are provided for each channel based on channel type) |
| iPack options | • iPack configured via serial port connection to your PC • serial connection direct to iPack or through logger's iPack access port • Symphonie Data Retriever for Windows integrates iPack settings |
| Connections | |
| Sensor wiring | • sensors connect to removeable field wiring panel • ground stud connects to earth ground with included ground cable • male DB25 interfaces to one optional iPack communications module • iPack access port facilitates field programming and accepts headset for voice calls • 3 SCM slots for counter channels 4, 5, 6 • 4 SCM slots for analog channels 9, 10, 11, 12 |
| Power requirements | |
| Batteries | • (2) 1.5 Volt D-Cell Batteries (included) • nominal voltage: 1.5 Volts • minimum voltage: 0.9 Volts • battery life approximately one year, depending on configuration |
| External power input | • provided by an optional iPack |
| External solar input Other | • provided by an optional iPack • optional iPacks provide 12V power (20mA max.) • PV/Battery only iPack provides power to sensors and logger for stand alone configurations |
| Installation | |
| Mounting | • mounts with 4 bolts (included) to keyed slots inside of
metal shelter box • shelter box mounts to tower with hose clamps |
| Tools required | • screwdriver for input terminals, included • 8 mm (5/16 inch) wrench or nut driver for logger mounting screws • 3/8 inch wrench or nut driver for logger ground nuts |
| Environmental | |
| Operating temperature range | -40°C to 65°C (-40°F to 149°F) Note: display readable -30°C to 55°C (-22°F to 130°F) |
| Operating humidity range | 0 to 100% RH non-condensing |
| Lifespan | 10 years + |
| Physical | |
| Weight | 1.3 kg (2.6 pounds), including batteries |
| Dimensions | 22.2 cm (8.7”) h x 18.8 cm (7.4”) w x 7.7 cm (3.0”) d, including field wiring panel |
| Materials | |
| Faceplate | injection molded black ABS |
| Buttons | white elastomer dome keypad |
| Wiring panel | fiberglass-epoxy terminal board, sealed gold plated pins, zinc plated screws and terminals |
| Enclosure | weatherproof polycarbonate, meets the following
specifications: • NEMA type 4, 4X and 13 • IEC: IP65 |
| Order Information |
| Cat. No. | Description |
| 4289 | SymphoniePLUS 15-channel data logger |