GENEQ > Biotechnology > Hoods

TableTop Clean Room
 


FEATURES
  • Dust free pharmaceutical packaging
  • Q/A testing in 'dirty' plant setting
  • Assembly of sensitive optical components
  • Electronics assembly
  • Further reduces particle count in existing cleanrooms
  • Can be used with carbon filters to prevent chemical contamination of samples inside the hood
Localized Clean Room Purity at a Fraction of the Cost
The RF-1000 reverses the usual airflow direction to create a dust-free work area of better than 100 ppm for highly sensitive samples or instruments. The portable tabletop clean room provides a particle and bacteria free work area for a fraction of the cost of a full size clean room. Protect products and samples from contamination with Class 100 or better clean air.

The HEPA Filter is rated 99.99% efficient at 0.3 microns. The variable speed control allows the air flow to be reduced when you are working with sensitive samples. The enclosure measures 24" wide x 18" high x 18" deep and has a 1/2" clear acrylic top for easy viewing, 3/8" clear acrylic side panels and a 1/2" white polyethylene floor. The RF-1000 is also available in a variety of custom sizes.

OPTIONS
  • Light Kit
  • Blocked Filter Alarm Unit
  • Acrylic Polish - Anti Static Surface Cleaner
  • Air Flow Alarm Unit

SPECIFICATIONS
Model No RF-1000 Tabletop Clean Room
Overall Size 24"W x 18"D x 30.25"H
Workspace 23.25"W x 17.5"D x 17"H
Power Requirements 115V AC, 100 Watts, 50/60 Hz, 230V AC optional for export
Weight 65 lbs.
Blower 530 CFM, (free air), Backward Curved Impeller
Noise Level A weighted noise level 68 dB at 1 meter

AIRFLOW PERFORMANCE STATISTICS
Filters Installed
Max Airflow
CFM
Face Velocity
FPM
HEPA & Dacron
205
230
All numbers refer to average readings taken at full blower speed
Please note: we can manufacture this unit in many different sizes and/or configurations.