GENEQ > Biotechnology > Dataloggers
4 Channel Humidity/Temperature Logger with Internal Sensors
and External Probe Socket
Testo 177-H1

| ADVANTAGES OF THE HUMIDITY SENSOR |
| The humidity sensor, developped by Testo, has been tried and tested throughout the world. The use of the sensor in the humidity data logger results in the following excellent properties: |
|
| IDEAL FOR AIR HUMIDITY AND TEMPERATURE MONITORING |
|
| EXAMPLE OF APPLICATION IN DOMESTIC BUILDING | |
![]() |
Building defect of incorrect
ventilations? Moisture on ceilings and walls can be caused by faults in the building. However, in most cases it is a sign of incorrect ventilation. Long term measurement with a data logger will clarify the situation. The data logger calculates the difference based on the wall surface temperature and the dew point temperature of the ambient air. If it is established that the room was aired on a regular basis and the walls are still moist (dew point temperature is higher than the wall surface temperature), then there must be a defect in the building or insulation is insufficient. |
| SPECIFICATIONS | |
| Parameters | Humidity/Temperature/Dew Point |
| Sensors | Humidity sensor NTC (internal) / NTC (external) |
| No. of Channels | 4 channels (3 x int. %RH; °C, °C td) (1 x external °C) |
| Measuring Range | 0...100%RH -20 to +70°C (internal) -40 to +70°C td -40 to +120°C (external) |
| Resolution | 0.1% RH / 0.1°C / 0.1°C td |
| Accuracy/System | ±2%RH |
| Internal ±1 Digit | ±0.5°C |
| Accuracy/Instr. | ±0.2°C; -25 to +70°C |
| External ±1 Digit | ±0.4°C rem. range |
| Memory | 48,000 readings |
| Application Temp. | -20 to +70°C |
| Storage Temp. | -40 to +85°C |
| Battery Type | Lithium (1AA) |
| Weight | 130g |
| Protection Class | IP 54 |
| CAT. NO. | DESCRIPTION |
| 0563 1775 | 4 Channel humitidy/temperature logger with internal sensors and additional external probe socket, wall holder and calibration protocol |
| Accessories | |
| 0554 1774 | Comsoft 3 - Basic set, easy-to-use software with diagram and table function, interface for logger. Includes desktop holder |
| 0554 1775 | Testo 575 fast printer |
| 0554 1778 | Testo 580 data collector. Includes readout holder for logger |
| Calibration Certificates | |
| 0520 0246 | DKD calibration certificate/temperature Temperature data loggers; cal points 11.3%RH and 75.3%RH at +25°C; for each channel/instr. |
| 0520 0076 | ISO calibration certificates-temperature Temperature data loggers; cal points 11.3%RH and 75.3%RH at +25°C; for each channel/instr. |
| 0520 0261 | DKD calibration certificate/temperature Temperature data loggers; cal points -20°C; 0°C; +60°C; for each channel/instr. |
| 0520 0151 | ISO calibration certificates-temperature Temperature data loggers; cal points -18°C; 0°C; +60°C; for each channel/instr. |