GENEQ > Biotechnology > Dataloggers
Probes for Testo 175 / 177
| ACCURATE NTC PROBES FOR TESTO 175-T2, 177-T3, 177-H1 DATA LOGGERS |
| CAT NO.: 0628 7510 | |||
![]() |
Stub Probe
IP 54 |
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-20 to +70°C
|
±0.2°C (-20 to +40°C)
|
15s
|
-
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0628 7503* | |||
|
Mounting probe with aluminium sleeve
IP 65 |
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-20 to 90°C
|
0 to 70°C = ±0.2K
|
60s
|
Fixed cable (2.4m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0610 1725* | |||
|
Accurate immersion / penetration probe
IP 67 |
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-35 to 80°C
|
±0.2°C (-25 to 74.9°C)
±0.4°C (-35 to 25.1°C) ±0.4°C (75 to 80°C) |
5s
|
Fixed cable (6m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0628 7514* | |||
|
Screw-in probe for measurements in difficult to access
places, M6 thread
IP 54 |
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 80°C
|
±0.5% of reading
(100 to 150°C) |
70s
|
Fixed cable (2m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0628 7516* | |||
|
Probe for surface measurement
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
50 to 80°C
|
±0.2°C (0 to 70°C)
|
150s
|
Fixed cable (2m)
|
| CAT NO.: 0628 7507 | |||
|
Wall surface temperature probe, e.g. as proof of damage
to building material
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
50 to 80°C
|
±0.2°C (0 to 70°C)
|
20s
|
Fixed cable (3m)
|
| CAT NO.: 0613 4611 | |||
|
Pipe probe with Velcro for pipe diameter of max. 75mm
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 70°C
|
±0.2°C (-25 to 70°C)
±0.4°C (-50 to -25.1°C) |
-
|
Fixed cable (1.5m)
|
| CAT NO.: 0613 2211* | |||
|
Food probe (IP 65) made of stainless steel, PUR cable
up to 80°C can be used, IP54 plug-in connection
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 150°C
|
±0.5% of read (100 to 150°C)
±0.2°C (-25 to -74.9°C) ±0.4°C (-50 to -25.1°C) ±0.4°C (75 to 99.9°C) |
8s
|
Fixed cable (1.5m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0613 2411* | |||
![]() |
Robust food penetration probe with special handle, IP
65, reinforced cable (PUR) and reinforced bending protection
|
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 150°C
|
±0.5% of read (100 to 150°C)
±0.2°C (-25 to -74.9°C) ±0.4°C (-50 to -25.1°C) ±0.4°C (75 to 99.9°C) |
7s
|
Fixed cable (1.4m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0613 3211* | |||
![]() |
Frozen food probe, no drilling required
|
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 140°C
|
±0.5% of read (100 to 140°C)
±0.2°C (-25 to -74.9°C) ±0.4°C (-50 to -25.1°C) ±0.4°C (75 to 99.9°C) |
20s
|
Plug-in cable (1.5m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0613 1711* | |||
|
Robust, affordable air probe, to check storage temperature,
for example
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 150°C
|
±0.5% of read (100 to 150°C)
±0.2°C (-25 to -74.9°C) ±0.4°C (-50 to -25.1°C) ±0.4°C (75 to 99.9°C) |
60s
|
Fixed cable (1.2m)
|
| * Probe tested in accordance with EN 12830 as to suitability for transport and storage |
| ACCURATE THERMOCOUPLE PROBES FOR TESTO 175-T3, 177-T4 DATA LOGGERS |
| CAT NO.: 0628 7533 | |||
|
Mounting probe with stainless steel sleeve
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 205°C
|
±1.5
|
20s
|
Fixed cable (1.9m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0628 0020 | |||
|
Pipe wrap probe with Velcro, for temperature measurement
on pipes with diameter to max. 120 mm, Tmax. 120°C
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-60 to 120°C
|
-
|
90s
|
Fixed cable (1.5m)
|
| CAT NO.: 0602 4592 | |||
![]() |
Pipe wrap probe with pipe diameter 5 to 65mm, with exchangeable
meas. head. Measuring range short-term to 280°C
|
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-60 to 130°C
|
Class 2
|
5s
|
Fixed cable (1.2m)
|
| CAT NO.: 0628 7521 | |||
![]() |
Mounted surface temperature probe with outer thread
M 14 x 1.5 and 2 nuts, quick action surface probe with cross-band
|
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 180°C
|
Class 2
|
3s
|
Fixed cable (2m)
|
| CAT NO.: 0602 0645 | |||
|
Thermocouple, flexible, 1500mm long, Teflon
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 400°C
|
Class 2
|
5s
|
-
|
| CAT NO.: 0602 0646 | |||
|
Thermocouple, flexible, 1500mm long, Teflon
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 250°C
|
Class 2
|
5s
|
-
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0602 5792 | |||
|
Immersion measurement tip, bendable
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-200 to 1000°C
|
Class 1
|
5s
|
-
|
| CAT NO.: 0602 4892 | |||
![]() |
Magnetic probe, adhesive force approx. 10N with adhesive
magnets, for higher temperatures, for measurements on metal surfaces
|
||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-50 to 400°C
|
Class 2
|
-
|
Fixed cable (1.6m)
|
| CAT NO.: 0602 1292 | |||
|
Water-tight immersion / penetration probe
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-60 to 400°C
|
Class 2
|
7s
|
Fixed cable (1.2m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0602 0592 | |||
|
Accurate and fast immersion probe, water-tight
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-60 to 1000°C
|
Class 1
|
2s
|
Fixed cable (1.2m)
|
| The protection class specified for the data logger is achieved with this probe | |||
| CAT NO.: 0602 1792 | |||
|
Robust, affordable air probe
|
|||
| Specifications | |||
|
Meas. Range
|
Accuracy
|
t99
|
Connection Cable
|
|
-60 to 400°C
|
Class 2
|
25s
|
Fixed cable (1.2m)
|