GENEQ > Materials > Temperature Recorders
| DICKSON TM320/325/725 |
| TEMPERATURE AND HUMIDITY LCD DISPLAY LOGGERS |
|
Introducing our best data loggers ever! Dicksons
new series of Temperature/Humidity Data Loggers with
Jumbo Display offer all of the key features youve been looking
for including: High/Low Alarm, Min/Max
Display, Super high-speed USB 2.0 Connectivity, One Step Data Transfer
using removable SD FLASH memory
cards and 1 Second Sample Rate. High Accuracy Temperature/Humidity
Models, Remote Probe Models and
Network Models Available.
|
| Additional Features: | |||
|
Model
|
Temperature Accuracy
|
Remote Probe
|
Network Connectivity
|
|
TM320
|
±0.8°F
|
||
|
TM325
|
±0.8°F
|
Yes
|
|
|
TM725
|
±0.8°F
|
Yes
|
Yes
|
|
Featuring our fastest data download ever! Download
data in just seconds, using new USB port compared to 1.5 minutes
Featuring our fastest data download ever! Download data in just
seconds, using new USB port compared to 1.5 minutes
using standard serial port. Or, leave the logger in the field and
use memory cards to transfer data to your PC. |
| Specifi cations: | ||
| Humidity |
Range: | 0 to 95% RH |
| Sensor: | Monolithic IC Humidity Sensor | |
| Accuracy: | ±2% RH @ 77°F (25°C) | |
| Temperature |
Range - Internal (TM320): | -4 to +158°F (-20 to +70°C) |
| Range - External (TM325 & TM725): | -40 to +185°F (-40 to +85°C) | |
| Sensor: | Thermistor | |
| Accuracy: | ±0.8°F (±0.5°C) | |
| Download: |
USB, Serial, or Memory Card | |
| Ambient Operating Conditions (logger only): |
-4 to +158°F (-20 to +70°C); 0 to 95% RH non-condensing | |
| Storage Conditions (logger only): |
-40 to +176°F (-40 to +80°C), 0 to 100% RH non-condensing; | |
| Probe: |
-40 to +185°F (-40 to +85°C), 0 to 100% RH non-condensing | |
| Keypad - Type/Functions: | 3 buttons with tactile feedback; Min/Max,
Alarm, Download |
|
| Response Time: |
1 min. to 63% FS, typical | |
| Display: | 2.0 x 1.375 V.A. 4 digit LCD,
TN positive mode, Refl ective |
|
| Resolution - Logger: | 0.1° From 0.0 to 999.9; 1° over
1000 |
|
| Power Supply - Type: |
TM320 & TM325: | Batteries, 4 AA Alkaline, AC adapter - optional; |
| TM725: | AC Adapter | |
| Battery - Type/Life: |
TM320 & TM325: | AA alkaline, user replaceable; 6 months typical @ 1 minute sample intervals; |
| TM725: | 9 V battery (backup only) | |
| AC Adapter (Included with TM725 only):
|
Input Voltage/Current: 120VAC / 60Hz / 16W; Output Voltage/Current: 9VDC / 1A; | |
| Input Connection: |
Plugs directly into outlet; Output Connection: 3.5mm phone plug; Length: 6 feet | |
| Sample Interval: | Variable from 1 sec. to 24 hours in 10
sec increments |
|
| Memory Type: |
EEPROM, Removable Flash Storage Device | |
| Number of Samples: |
32,000 (16,000 per channel) measurements | |
| Alarms - Types: |
High/Low Audible alarm | |
| Approvals: |
CE | |
| Calibration: | User: zero pt.; Factory: zero and span |
|
| Enclosure - Type: |
Polycarbonate | |
| Mounting: | Wall mountable via keyhole slots |
|
| Dimensions - Enclosure: | 4.0 (10.2 cm) x 3.0 (7.7 cm)
x 1.6 (3.9 cm) |
|
| Weight: |
9 oz. | |
| Includes: | Batteries, instruction manual | |
| DicksonWare & Download Cable Specifi cations: | |
| DicksonWare Minimum
Version Required: |
Compatible With: |
| Models TM320 & TM325: DicksonWare
version 8.3 Model TM725: DicksonWare SECURE version 8.3 |
A015/A025: Microsoft Windows® 95, 98,
2000, NT and XP; A016/A026: Microsoft Windows® 98, 2000, and XP |
| PC Requirements: | Cable Type/Length: |
| PC with 486 MHz or faster microprocessor,
4 MB RAM (A015), 16 MB RAM (A016/A026/A025), 1 free COM (serial) port with dedicated interrupt (A015/A025) or 1 USB root hub (A016/A026), CD drive, VGA monitor or better |
A015/A025: 9 pin female D-shell to male
2.5mm stereo plug, 6 feet; A016/A026: USB male series A plug to 5-pin male series B mini plug, 6 (2 meters) |
| Computer Interface: |
Network Connection (TM725): |
| RS-232 serial (COM) port or USB | Standard Ethernet |
| Ordering Information | |
| Description |
Order No. |
| Midsize Display Temperature
& Humidity Data Logger |
TM320 |
| Midsize Display Temperature
& Humidity Data Logger w/ Remote Probe |
TM325 |
| Midsize Display Temperature & Humidity Network Data Logger w/ Remote Probe | TM725 |
| Accessories | |
| DicksonWare Software and
USB Cable - English |
A016 |
| DicksonWare Software and
Serial Cable - English |
A015 |
| DicksonWare SECURE Software
and USB Cable (21CFR11 Compliant) - English |
A026 |
| DicksonWare SECURE Software
and Serial Cable (21CFR11 Compliant) - English |
A025 |
| DicksonWare Software and
USB Cable - French |
A036 |
| DicksonWare Software and
Serial Cable - French |
A035 |
| DicksonWare SECURE Software
and USB Cable (21CFR11 Compliant) - French |
A038 |
| DicksonWare SECURE Software
and Serial Cable (21CFR11 Compliant) - French |
A037 |
| DicksonWare Software and
USB Cable - Spanish |
A046 |
| DicksonWare Software and
Serial Cable - Spanish |
A045 |
| DicksonWare SECURE Software
and USB Cable (21CFR11 Compliant) - Spanish |
A048 |
| DicksonWare SECURE Software
and Serial Cable (21CFR11 Compliant) - Spanish |
A047 |
| Removeable FLASH Storage Device |
A210 |
| Card Reader Kit |
A220 |
| NIST Traceable Calibration 1-pt.
(new units) |
N100 |
| NIST Traceable Calibration 3-pt.
(new units) |
N300 |
| A2LA Accredited Calibration 3-pt. (new
units) |
N400 |
| Certifi cate of Validation |
N520 |
| Logger Calibration Software |
SW400 |
| AC Adapter (recommended for continuous
display) |
R157 |
| Extra Serial Logger Download Cable |
A060 |
| Extra USB Logger Download Cable |
A061 |
| RH Calibration Kit (12% & 75%) for
use with TM125 only |
A834 |
| Probe Dust Filter (TM325 only) | A867 |