- Functioning of an electricity production unit
- Steam boiler
- Steam turbine
- Alternator
- Efficiency
- Measuring devices on different circuits
- Temperature
- Level
- Pressure
- Flow
- Efficiency calculation
- Steam boiler
- Superheater
- Steam turbine
- Steam condenser
- Cooling tower
- Study and analyse on water treatment system
|
- Steam flow in kg/h with vortex flowmeter for steam
- Scale : 0-200 kg/h of steam
- Cooling water flow on the condenser with flowmeter
- Scale : 0-10 m3/h
- Precision : ± 3 % full scale
- Temperatures : 9 thermometers with needle
- condenser water inlet
- condenser water outlet
- steam boiler outlet
- steam superheater outlet
- steam turbine inlet
- steam turbine outlet
- condensate
- water tank
- Fuel temperature in the tank
- Pressure : 7 manometers with needle
- Steam boiler outlet
- Steam turbine inlet
- Steam turbine outlet
- Steam utility circuit
- Water feeding
- Steam condenser inlet
- Steam condenser outlet
- Speed of the turbine with digital indicator
- Scale : 0-4000 rpm
- Precision : 0,1%
- Electric power with digital indicator
- Scale : 0-1000 Watts
- Precision : 0,5 %
|

- Steam boiler 81 000kcal/h
Permanent presence boiler with safety (level control, security pressure control, valve...)
Electric cabinet with alarms
Maximum temperature 192°C
Steam production 135Kg/h
Maximum pressure12 bars
Burner fuel (possibility natural gas)
- Steam turbine
Steam turbine 1kW
Turn speed : 3600rpm
Pressure supplying :12 bars
Mechanic regulation of overspeed
Shut valve
- Alternator
Mechanic connecting to the turbine
Production : 1000W-50hz à 3600rpm
Production control thanks to potentiometer
Dissipation of energy on electric
- Cooling turn
Open tower with forced
Power : 130KW
Open air circuit with flow 1.2m3/s
Direct current water circuit with flow 12 m3/h
- Steam condenser
Tubular exchanger (water in tubes)
Exchange surface 1.4m²
Condensates are pumped back to the water tank
- Water tank
Volume : 250L
Material : stainless steel
Control : level, temperature
Heating by steam with injector
Feeding pump for the boiler
- Fuel tank
Volume : 250L
Material : stainless steel
Control : level, temperature
Retention tank under the fuel tank
- Water treatment
Automatic softener with regeneration of resin
Salt tank 100L
Water treatment by addition of specific product thanks to dosing pump
|