GENEQ > Environment > Air Velocity Meters
| VELOCICALC® Multi-Function Ventilation Meter |
| model 9565 |
| Description |
| VELOCICALC® Multi-Function Ventilation Meter Model 9565 The VELOCICALC® Model 9565 series are portable, handheld, Multi-Function Ventilation Test Instruments featuring a menudriven user interface for easy operation in your local language. On-screen prompts and step-by-step instructions guide the user through instrument setup, operation, and field calibration. The 9565 also features an ergonomic, overmolded case design with probe holder and a keypad lockout to prevent tampering during unattended use. These instruments are available with or without a differential pressure sensor and are designed to work with a wide range of plug-in probes. |
| Features and Benefits |
|
| Applications |
|
| VELOCICALC Plug-In Probes |
| The plug-in probes allow users to make various measurements by
simply plugging in a different probe that has the features and functions
best suited for a particular application. Plug-in probes for the VELOCICALC series can be ordered at any time and include a data sheet with certificate of traceability. When it’s time for servicing, only the probe needs to be returned since all the calibration data is stored within the probe. |
| Thermoanemometer Air Velocity Probes |
| TSI offers four models featuring multiple measurements in a compact,
robust probe design. These telescopic probes are available in straight or
articulating construction, and with or without a relative humidity sensor. Models with a relative humidity sensor can also calculate wet bulb and dewpoint temperature. Common applications include duct traversing, face velocity testing of chemical fume hoods, biological safety cabinets and HEPA filters. When combined with the 9565, advanced measurement applications can be performed including heat flow, draft rate and turbulence intensity. |
| Rotating Vane Anemometer Probes |
| Rotating vane probes are available in 1.5” (35 mm) and 4” (100 mm) diameters, and measure air velocity and temperature with flow calculation. Measurement applications include face velocity as well as air velocity in turbulent airstreams. An optional telescopic articulating probe is available for both models, and an Aircone kit is available for the 4” vane head model. |
| Pitot Probes and Airflow Probe 800187 |
| Pitot probes are used to obtain air velocity and air volume
measurements within ductwork by performing a duct traverse. Consult
factory for sizes and part numbers. The Airflow Probe Model 800187 is an 18” (46 cm) straight Pitot probe that can be used to perform duct traverses and are ideally suited for measuring in small diameter ductwork. ![]() |
| LogDat2™ Downloading Software |
The VELOCICALC Model 9565 Series includes downloading software
called LogDat2. LogDat2 software transfers the stored data from the
Model 9565 to a computer as a spreadsheet file. This software is useful
for applications such as duct traverses, fume hood, and filter face
velocity testing.![]() |
| Data Collection and Reporting |
Expanded data logging capacity and the inclusion of TRAKPRO Data
Analysis Software provides the capabilities to work more effectively and
efficiently. The 9565 can store up to 38.9 days of data collected at oneminute
log intervals. The stored data can be recalled, reviewed on
screen, and downloaded for easy reporting.
|
| Probe Specifications Models 960, 962, 964, 966, 496, 995, 980, 982, 792, 794, 984, 985, 986, and 987 |
| 960 Thermoanemometer Straight Probe Velocity and Temperature Range 0 to 9,999 ft/min (0 to 50 m/s) 0 to 200°F (-18 to 93°C) Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater4&5 ±0.5°F (±0.3°C)6 Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 962 Thermoanemometer Articulating Probe Velocity and Temperature Range 0 to 9,999 ft/min (0 to 50 m/s) 0 to 200°F (-18 to 93°C) Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater4&5 ±0.5°F (±0.3°C)6 Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 964 Thermoanemometer Straight Probe Velocity, Temperature and Humidity Range 0 to 9,999 ft/min (0 to 50 m/s) 14 to 140°F (-10 to 60°C) 5 to 95% RH Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater4&5 ±0.5°F (±0.3°C)6 ±3% RH7 Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 966 Thermoanemometer Articulating Probe Velocity, Temperature and Humidity Range 0 to 9,999 ft/min (0 to 50 m/s) 14 to 140°F (-10 to 60°C) 5 to 95% RH Accuracy ±3% of reading or ±3 ft/min (±0.015 m/s), whichever is greater4&5 ±0.5°F (±0.3°C)6 ±3% RH7 Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 496 Rotating Vane 1.5 in. (35 mm) Velocity and Temperature Range 100 to 3,000 ft/min (0.50 to 15.00 m/s) 32 to 140°F (0 to 60°C) Accuracy ±3% of reading ±4 ft/min (±0.02 m/s) ±2.0°F (±1.0°C) Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 995 Rotating Vane 4 in. (100 mm) Probe Velocity and Temperature Range 50 to 6,000 ft/min (0.25 to 30 m/s) 32 to 140°F (0 to 60°C) Accuracy ±1% of reading ±4 ft/min (±0.02 m/s) ±2.0°F (±1.0°C) Resolution 1 ft/min (0.01 m/s) 0.1°F (0.1°C) 980 IAQ Probes C02, Temperature and Humidity Range 0 to 5,000 ppm CO2, 5 to 95% RH, 14 to 140°F (-10 to 60°C) Accuracy ±3% of reading or ±50 ppm, whichever is greater9 CO2 ±3% RH7 ±1.0°F (±0.6°C)6 Resolution 1 ppm CO2 0.1% RH 0.1°F (0.1°C) 982 IAQ Probes Model CO, C02, Temperature and Humidity Range 0 to 500 ppm CO 0 to 5000 ppm CO2 5 to 95% RH 14 to 140°F (-10 to 60°C) Accuracy ±3% of reading or ±3 ppm, whichever is greater8 CO ±3% of reading or ±50 ppm, whichever is greater9 CO2 ±3% RH7 ±1.0°F (±0.6°C)6 Resolution 0.1 ppm CO 1 ppm CO2 0.1% RH 0.1°F (0.1°C) 792 and 794 Thermocouple Probes Temperature Range -40 to 1200°F (-40 to 650°C) Accuracy ±0.1% of reading +2°F (±0.056% of reading +1.1°C) Resolution 0.1°F (0.1°C) 984 Low Concentration (ppb) VOC and Temperature Range 10 to 20,000 ppb, -10 to 60°C (14 to 140°F) Accuracy ±0.5°C (±1.0°F)1 Resolution Up to 10 ppb, 0.1°C (0.1°F) 985 High Concentration (ppm) VOC and Temperature Range 1 to 2,000 ppm, -10 to 60°C (14 to 140°F) Accuracy ±0.5°C (±1.0°F)1 Resolution Up to 10 ppm, 0.1°C (0.1°F) 986 Low Concentration (ppb) VOC, Temperature, CO2, and Humidity Range 10 to 20,000 ppb, 0 to 5,000 ppm CO2 -10 to 60°C (14 to 140°F), 5 to 95% RH Accuracy ±3% of reading or 50 ppm, whichever is greater ±0.5°C (±1.0°F)1, ±3% RH2 Resolution Up to 10 ppb, 0.1 ppm CO2, 0.1°C (0.1°F), 0.1% RH 987 High Concentration (ppm) VOC, Temperature, CO2, and Humidity Range 1 to 2,000 ppm, 0 to 5,000 ppm CO2 -10 to 60°C (14 to 140°F), 5 to 95% RH Accuracy ±3% of reading or 50 ppm, whichever is greater ±0.5°C (±1.0°F)1, ±3% RH2 Resolution Up to 10 ppm, 0.1 ppm CO2, 0.1°C (0.1°F), 0.1% RH |