GENEQ > Environment > pH Meters
Versatile Instrument for Water Conditioning
Model HI9812
Calibration has been simplified to one point for
both pH and conductivity/TDS modes. HI 9812 is equipped with Automatic Temperature
Compensation to remove the effects of temperature on your conductivity and TDS
measurements. In addition, the BEPS (Battery Error Preventive System) will alert
the user when low batteries could affect the readings. This portable meter uses
4-in-1 replaceable HI 1285 probe. No probe changes are required when switching
your measured parameter between pH, conductivity and TDS. The specially engineered
pH electrode also features a fiber junction and gel electrolyte for faster response
and reduced contamination.
| FEATURES |
| Multiparameter Probe |
| The HI 1285 allows easy parameter changes with the push of a button. |
| Simplify Your Measurements |
| With the HI 9812 it is no longer necessary to constantly change instruments, probes or test kits for your routine measurements. |
| ATC |
| The built-in temperature sensor allows all conductivity and TDS measurements to be compensated against the effects of temperature. |
| SPECIFICATIONS | |
|
HI9812
|
|
| Range (pH) | 0.0 to 14.0 pH |
| Range (EC) | 0 to 1990 µS/cm (µmho/cm) |
| Range (TDS) | 0 to 1990 mg/L (ppm) |
| Resolution (pH) | 0.1pH |
| Resolution (EC) | 10µS/cm |
| Resolution (TDS) | 10mg/L |
| Accuracy (pH) (@20°C/68°F) |
±0.2 pH |
| Accuracy (EC) (@20°C/68°F) |
±2% F.S |
| Accuracy (TDS) (@20°C/68°F) |
±2% F.S. |
| Typical EMC Deviation (pH) | ±0.1 pH |
| Typical EMC Deviation (EC) | ±2% F.S. |
| Typical EMC Deviation (TDS) | ±2% F.S. |
| Calibration | Manual 1 point through trimmer for all parameters |
| Temp. compensation | Automatic from 0 to 50°C (50 to 122°F) with ß of 2% per °C (conductivity/TDS only) |
| Probe | HI1285 pH/conductivity/TDS probe with Din connector and 1m (3.3') cable (included) |
| Battery type / life | 1 x 9V/150 hours approx. continuous use |
| Environment | 0 to 50°C (32 to 122°F); RH 95% |
| Dimensions | 185 x 82 x 45mm (7.3 x 3.2 x 1.8") |
| Weight | 520g (1.1 lb) |
| CAT. NO. | DESCRIPTION |
| HI9812 | Supplied complete with HI 1285 probe with 1 m (3.3) cable, pH 7 buffer (20 mL), 1413 µS/cm and 1382 ppm calibration solutions (20 mL each), 9V battery and instruction manual. |
| HI 1285 | 4-in-1 pH/EC/TDS/°C probe |
| HI 710001 | Soft carrying case |
| HI 721312 | Rugged carrying case |
| HI 710009 | Blue rubber boot |
| HI 710010 | Orange rubber boot |
| HI 70300L | Storage solution, 460 mL |
| HI 7061L | Cleaning solution, 460 mL |
| HI 77100P | pH 7 and 1413 µS/cm calibration solutions (20 mL, 10 pcs each) |
| HI 77300P | pH 7 and 1382 ppm calibration solutions (20 mL, 10 pcs each) |
| HI 77400P | Cal. kit (pH 4 & 7, 20 mL, 5 pcs each) |