Sondes à COV pour appareils multi tâches |
| modèle 984, 985, 986 et 987 de TSI |
| Features and Benefits |
|
| Applications |
|
| Data Collection and Reporting |
| Expanded data logging
capacity and the inclusion of
TRAKPRO Data Analysis
Software provides the
capabilities to work more
effectively and efficiently. The Q-TRAK monitor can store up to 38.9 days of data collected at one-minute log intervals. The stored data can be recalled, reviewed on screen, and downloaded for easy reporting. TRAKPRO software helps you to generate professional graphs for your reports. |
| Field Service |
TSI VOC probes are competitively priced to others in the marketplace
but feature a lower cost of ownership due its compact design and
construction which is geared for field service capability.
|
![]() |
| Instrumentation |
| The 7575 Q-TRAK monitor or 9565 VELOCICALC meter feature a menudriven
user interface for easy operation. VOC probes are also
compatible with AIRFLOW™ Instruments TA460 series and TSI’s
discontinued 7565 and 9555 series, if instrument firmware is at
revision 2.10 or higher. On-screen prompts and step-by-step instructions guide the user through operation and field calibration. These instruments also feature an ergonomic, over molded case design and a keypad lockout to prevent tampering during unattended use.
|
| Specifications |
| Model 984 Low Concentration (ppb) VOC and Temperature Range 10 to 20,000 ppb, 14 to 140°F (-10 to 60°C) Accuracy ±1.0°F (±0.5°C)1 Resolution Up to 10 ppb, 0.1°F (0.1°C) Model 985 High Concentration (ppm) VOC and Temperature Range 1 to 2,000 ppm, 14 to 140°F (-10 to 60°C) Accuracy ±1.0°F (±0.5°C)1 Resolution Up to 10 ppm, 0.1°F (0.1°C) Model 986 Low Concentration (ppb) VOC, Temperature, CO2, and Humidity Range 10 to 20,000 ppb, 0 to 5,000 ppm CO2 14 to 140°F (-10 to 60°C), 5 to 95% RH Accuracy ±3% of reading or 50 ppm, whichever is greater ±1.0°F (±0.5°C)1, ±3% RH2 Resolution Up to 10 ppb, 0.1 ppm CO2, 0.1°F (0.1°C), 0.1% RH Model 987 High Concentration (ppm) VOC, Temperature, CO2, and Humidity Range 1 to 2,000 ppm, 0 to 5,000 ppm CO2 14 to 140°F (-10 to 60°C), 5 to 95% RH Accuracy ±3% of reading or 50 ppm, whichever is greater ±1.0°F (±0.5°C)1, ±3% RH2 Resolution Up to 10 ppm, 0.1 ppm CO2, 0.1°F (0.1°C), 0.1% RH Probe Dimensions Length 7.0 in. (17.8 cm) Base Diameter 0.75 in. (1.9 cm) Tip Diameter 1.0 in. (2.54 cm) Note: The 984 and 986 probes are designed to measure ppb concentrations of VOCs. The 10 to 20,000 ppb range corresponds to 0.01 to 20 ppm. 1/ Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F (0.03°C/°C) for change in instrument temperature. 2/ Accuracy with probe at 77°F (25°C). Add uncertainty of 0.1% RH/°F (0.2% RH/°C) for change in probe temperature. Includes 1% hysteresis. |