Geneq > Environnement > Contrainte thermique – Moniteurs

Moniteur de contraintes thermiques
Modèle WB-300


Description
Heat stress can result in heat-induced illness and potentially serious workplace downtime. The 3M™ WIBGET™ Heat Stress Monitor WB-300 helps you to quickly and easily detect key environmental factors that can contribute to heat stress. The durable, yet lightweight heat stress monitor delivers high performance area monitoring using Wet Bulb Globe Temperature (WBGT) measurements for assessing environmental heat stress. The monitor’s durable design readily withstands the rigors of the workplace, and its easy-to-use features and simple operation make the WIBGET WB-300 an ideal monitor to help you to establish your heat stress management program.

Features
Reliable
One-year warranty

Fast Response
Direct reading of Wet Bulb, Dry Bulb,
Vernon Globe equivalent, WBGTin,
and WBGTout temperatures

Accurate
Displays to 1/10th degree

Easy Operation
At the push of a button, the 3MTM
WIBGETTM Heat Stress Monitor WB-300
calculates WBGT, helping you establish
appropriate work/rest ratios.

Specifications
Measurements Globe, dry bulb, wet bulb, WBGTi (WBGT indoor) and WBGTo (WBGT outdoor)
Temperatures given in Celsius or Fahrenheit
Languages English, French, Spanish, Italian, German
Housing Designed water resistant to a light rain or mist
Size Height 9.2in (23.5cm); Width 7.2in (18.3mm); Depth 3.0in (7.5mm), with mounted sensor assembly
Weight 2.6 lbs. (1.2 kg) with mounted sensor assembly
Sensors Temperature: 1000 ohm platinum RTD
Accuracy Temperature: +/- 0.9oF between 32o F to 212o F (+/-0.5oC between 0oC and 100oC)
Operating Temperature Range Sensor Assembly: 23oF to 212oF (-5oC to +100oC); Electronics: 23oF to 140oF (-5o C to 60o C)
Power Options 9V alkaline, 7.2V NiMH rechargeable pack (charged in the unit), or AC adapter wall power cube
(AC adapter will power the unit or recharge the NiMH battery pack)
Battery Life 9V alkaline: 140 hours; Rechargeable Nickel Metal Hydride: 300 hours
Charge Time (NiMH Battery Pack) 16 hours (charge in the unit)
Safety Approvals and Special Conditions CE mark; compliance with EN 50014: 1997, and EN 50020: 2002 Environmental Safety Div.