| Petit affichage |
| modèle WM44 SS |
| Introduction |
Small panel display unit and wind speed sensor with prealarm
and alarm. With 20 mm digits (0.8” display unit). Ideal
in conjunction with the Anemo4403 sensor. |
| Features |
| DISPLAY: Wind data displayed with two 20 mm digits. 2 alarm indicator LEDs enabled “AL1 and AL2”. Wind speed in km/h and mph. Programming in kilometres/hour ( km/h) or in miles/hour (mph). P01 You can switch between km/h and mph at any time by pressing “Select”, a user accessible button. ALARMS: The alarm is triggered when the programmed value is reached or surpassed and it has includes a delay to prevent false alarms due to short gusts. The alarm is disabled when the wind speed drops below the programmed value and provided this condition persists for a minimum period. When ALARM 2 is enabled ALARM 1 is disabled. When ALARM 2 is enabled, the reading on the display will blink, as a warning. |
Alarms can be programmed for the following: trigger values, intermittent or continuous, interlocked (only alarm2). The alarm outputs are through voltage-free relay contacts. Choice between: on contact open or on contact close. Possibility of alarm interlock 2. With the alarm disabled when the unit’s power supply is cut off. ANEMOMETER SENSORS: Suitable for a wide range of sensors: Power supply sensors: 20 V or 10 VDC, from the unit itself. types : 3-wire and 2-wire (see examples on faceplate connections from the unit itself). We RECOMMEND pairing the unit with our Anemo4403 model. PRESET USER PROGRAM CONFIGURATION. In addition to user-programmed another, alternative programming can be saved in memory. This can be retrieved any time by going to the program step. P00 option 4. |
| Technical characteristics |
| Power supply | 24 VAC 50-60 Hz not insulated. | Reading precision ( 100 Hz=100 km/h ) |
+/- 1 |
| Power consumption | < 3 VA | Maximum speed | 99 km/h /61 mph |
| Input signal | periodic square, sine-wave, from a sensor that obtains its power supply from the unit itself. 1 to 750 Hz . |
Relay contacts | 4 Amps 250 VAC. |
| Non-condensing relative humidity in accordance with IEC 68-2-3 and IEC 68-2-27 |
|||
| Input impedance | -For Anemo4403 sensor or namur connection : 1000 Ω | Shocks in accordance with IEC 68-2-27 |
|
| Compatible sensors | - Sensor mod. onix Anemo4403 - 3-wire sensors (pnp,npn..) - namur - Dose not admit direct external signals. - Sensors should be supplied with power from the unit itself. |
Vibrations in accordance with IEC 68-2-6 |
|
| Output power supply sensors | 10 or 20 VDC (+-10%) | Faceplate IP level | IP 501 |
| Operating temperature | -20 to 70 °C | Approximate weight | 110 g |
| Connections |
![]() |
| Dimensions |
![]() |