GENEQ > Biotechnology > pH Meters

Waterproof pH/ORP and Temperature Meters
Models HI991001 & HI991002

The HI 991001 and HI 991002 meters from Hanna offer IP 67 waterproof protection in a compact casing. The included multi-parameter electrode has a built-in temperature sensor. No additional temperature probe is required. The electrode also contains a mini amplifier to render your measurements impervious to noise and electrical interference. The large display shows readings in an extended range from -2.00 to 16.00 pH and simultaneously shows temperature from -5.0 to 105.0 °C or 23 to 221°F. HI 991002 also measures ORP from -1999 to 1999 mV. The mV scale of this meter can be used with the available HI 1296D pH/temperature electrode to check the condition of the pH electrode.

These meters have a stability indicator and hold feature that prompts you when to take the reading & freezes the display for easy and accurate recording. The large display also has graphic symbols to guide you through all operations. The battery life of the meters guarantee over 1500 hours of continuous use. At startup, they perform a self-check and then display the remaining battery level to assure proper working condition. Calibration is performed automatically at one or two points using standard or N.I.S.T. buffers.

SPECIFICATIONS
pH Range
-2.00 to 16.00
-2.00 to 16.00
ORP Range
-
±1999 mV
Temperature Range
-5.0 to 105.0°C or 23.0 to 221.0°F
-5.0 to 105.0°C or 23.0 to 221.0°F
pH Resolution
0.01
0.01
ORP Resolution
-
1 mV
Temperature Resolution
0.1°C or 0.1°F
0.1°C or 0.1°F

pH Accuracy
(@20°C/68°F)

±0.02
±0.02
ORP Accuracy
(@20°C/68°F)
-
±2 mV
Temperature Accuracy
(@20°C/68°F)
±0.5 up to 60°C, ±1°C up to 105°C
±1°F up to 140°F, ±2°F up to 221°F
±0.5 up to 60°C, ±1°C up to 105°C
±1°F up to 140°F, ±2°F up to 221°F
Typical EMC Deviation (pH)
±0.02
±0.02
Typical EMC Deviation (ORP)
-
±2 mV
Typical EMC Deviation (Temp.)
±0.2°C or ±0.4°F
±0.2°C or ±0.4°F
pH Calibration
Automatic 1 or 2 points with 2 set of standardized buffers (4.01, 7.01, 10.01 or 4.01, 6.86, 9.18)
Temperature Compensation
Automatic from -5 to 105°C (23 to 221°F) (for pH only)
Electrode
HI 1296D combination amplified pH/temperature with DIN connector and 1 m (3.3’) cable (included)
HI 1297D combination amplified pH/ORP/temperature with DIN connector and 1 m (3.3’) cable (included)
Battery Type / Life
3 x 1.5V AA / approximately 1500 hours of continuous use. Auto-off after 8 minutes
Environment
0 to 50°C (32 to 122°F); RH 100%
Dimensions
150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)
Weight
245 g (8.6 oz.)

CAT. NO. DESCRIPTION
HI 991001 Supplied complete with HI 1296D pH/temperature electrode, 3 x 1.5V AA batteries and carrying case.
HI 991002 Supplied complete with HI 1297D pH/ORP/temperature electrode, 3 x 1.5V AA batteries and carrying case.
Accessories
HI1296D Combination amplified pH/temperature electrode with DIN connector and 1 m (3.3’) cable
HI 1297D Combination amplified pH/ORP/temperature electrode with DIN connector and 1 m (3.3’) cable
HI 721312 Hard carrying case
HI 76405 Electrode Holder
HI 710007 Blue shockproof rubber boot
HI 7004L pH 4.01 buffer solution, 500 mL
HI 7007L pH 7.01 buffer solution, 500 mL
HI 7010L pH 10.01 buffer solution, 500 mL
HI 70300L Storage solution, 460 mL
HI 77400P Cal. kit (pH 4&7, 20 mL, 5 pcs each)