| Moniteur de la qualité de l'air intérieur modèle YESAIR Junior |
|
YESAIR Junior is a new low cost, light weight hand held device. It contains three key sensors that are aimed to simultaneously measure and record temperature, relative humidity, and carbon dioxide (CO2) levels in the air. The LCD display indicates all three sensors and measured values for each as well as battery status. |
| Key Features |
» Low cost & easy to use |
| Applications |
» Residential Buildings |
| Technical Drawing |
![]() |
| Technical Specifications | |||
| Gas Type | |||
| Carbon Dioxide (CO2) | |||
| Mechanical | |||
| Enclosure | Rugged ABS / Polycarbonate | ||
| Weight | 200 g (7.1 oz) | ||
| Size | 2.8" x 6.6" x 1.3" (70mm x 81mm x 32mm) | ||
| Display | 3 parameters, backlit, numerical LCD display | ||
| Electrical | |||
| Power Requirement | |||
| 4 x AA alkaline batteries | Up to 24 hours of operation time | ||
| 6 VDC wall adapter | 24/7 continuous operation time | ||
| Memory | Up to 26,000 data points to internal flash memory | ||
| Sensor | |||
| Sampling Method | Diffusion | ||
| Resolution | 1 ppm | ||
| Warm-Up Time | 30 seconds | ||
| Environmental (sensor dependant) | |||
| Operating Temperature | 0°C to 50°C (32°F to 122°F) | ||
| Humidity | 0 - 95% RH non-condensing | ||
| Certification | |||
| CE | Certified | ||
| Product Codes | |
| Carbon dioxide (CO2), temperature & relative humidity sensors plus internal data logging, Yes Viewer software, USB cable & carrying case. | YESAIR Junior |
| General |
The YESAIR junior is a rugged, hand-held, battery powered IAQ instrument for measuring and displaying Carbon Dioxide (CO2), Temperature & RH indoors. It opearates from internal alkaline batteries or it’s own (supplied) wall adapter (North American plus configuration only). |
| Specifications | |
| Dimensions | 2.75" W x 6.63" H x 1.25" Th (70mm x 81mm x 32mm) |
| Weight | 7.1 oz (200 grams) including batteries |
| General | Operating Conditions: |
| Operating Temeprature: 32-122°F (0-50°C) 0-95% RH, non-condensing Storage Temperature: -4 to 158°F (-20 to 70°C) |
|
| Power | Battery type: Alkaline, AA x 4 (20 to 24-hours) External: 9 VDC from external AC/DC adapter which is included in package (North American wall configuration only) Caution: DO NOT use rechargeable batteries in the YESAIR Junior and DO NOT try to use the wall adapter to charge them. Note: The end of the wall adapter that plugs into the instruments is 1.3mm diameter, centre positive (in case overseas customers want to source their own). |
| Warm up | 30-seconds |
| Outputs | USB to computer for use with the CETCI developed YESVIEWER PC software (cable supplied). |
| Sample Method | Diffusion |
| Range | 0-5000 ppm |
| Resolution | 1 ppm |
| Accuracy | +/- 30 ppm +/- 5% of reading (0 - 5000 ppm) |
| Pressure | Dependance: +1.6% reading per kPa deviation from normal pressure, 100 kPa |
| Temperature | Range: -10.0°C to 60.0°C (14°F to 140°F) Resolution: 0.1°C (0.1°F) Accuracy: +/- 0.6°C (+/- 0.9°F) |