Pollution control equipment

Pollution control equipment

Product Code:


Need more Info? (514) 354-2511 - 1-800-463-4363

BICKFORD PC-1 # 80005
Pressure Relief Pop-Off Valve with scavenging outlet. Replaces most older valves which do not have a scavenging outlet for carrying away waste gas overflow. Adjustable from fully open to fully closed with adjustable spring tension to set pop- off pressure. Transparent rotatable housing with standard 15 mm tapered male outlet connection, allows position and operation of the valve to be observed. Threaded base (3/4"-20) fits many anesthesia machines directly, others require an adapter.
Adapters for PC-1 Pop-Off Valve to various anesthesia machines

 

Cat. No. Make
341601
Drager
34131628
Dupaco
34131620
Ohio
341901
Matrx
347827
Foregger
347827
Stephens

 

BICKFORD PC-3 # 80015
Vacuum Scavenging Attachment Controls the drawing off of overflow gases from anesthesia breathing circuits for disposal into a hospital suction system.

 

Features
  • Mounts solidly to anesthesia machine providing terminal connection for suction supply.
  • Control valve built-in so that suction can be adjusted to equal input from anesthesia circuit avoiding excessive suction flows which may occur in installations with multiple O.R. sites.
  • Safety Relief Valve for positive and negative pressures to limit application of suction or back pressure to breathing circuit.
  • Breathing bag reservoir used to store pulsations of exhaled gases for evacuation with low continuous suction flow. Bag acts as a valuable indicator of in and out flow to and from system. 
  • Input connection standard 15 mm diameter external taper fits 7/8" breathing tubes and 15 mm internal diameter taper fits endotracheal tube connectors which are available for any size tubing.
  • Mounting brackets available to attach unit to most makes of anesthesia machines.
  • The BICKFORD PC-3 Vacuum Scavenging Attachment is used in semi-closed, open, or non- rebreathing systems, with an outlet connection provided. Most systems can be converted by replacing the present open type pressure relief (pop-off) valve with the BICKFORD PC-1 Valve and use of the BICKFORD PC-2 Non-rebreathing System.

 

# 80016
Mounting Bracket For F.S., Matrx and Drager
# 11140
Segmented Tubing Non-conductive blue corrugated segmented 7/8" I.O. hose sold by the foot
(please specify).

 

BICKFORD OMNICON F/AIR
Anesthesia Gas Filter Unit
A sensible answer to anesthesia gas problems in the operating room, the F/AIR anesthesia gas filter was specifically designed to remove waste anesthesia gases such as ISOFLURANCE, HALOTHANE, ENFLURANE, etc.from the operating room environment. Economical to use, with an average useful life of 12 to 15 hours, the F/AIR is easily adaptable to anesthesia machines. The F/AIR can remove no less than 50 grams of pure halogenated anesthetic gases and can then be conveniently discarded.

 

Cat. No. Description
80000
F/AIR Kit (one each), 80120, 80020 and 18007
80120
F/AIR Cannister Unit
80020
F/AIR Holder
08106
Endo. Tube Connector, 6mm
80005
BICKFORD PC-1 Pop-Off Valve
80010
BICKFORD PC-2A NRB System
18007
Scavenging Tube, 40" with 3 adapters
81915
Adapter, 15 mm I x 22 mm M
11140
Blue Plastic Scavenging Tubing with 22 mm cuffs at 6 inch intervals.
(specify length )
80122
Set of 3 adapters

 