SymphoniePLUS 15-channel Data Logger

SymphoniePLUS 15-channel Data Logger

Product Code:


Need more Info? (514) 354-2511 - 1-800-463-4363

Features
  • Proven
    • Pre-configured for the wind industry
  • More Anemometers
    • Up to nine anemometer channels — 15 channels total
  • Easy to use
    • Intuitive programming and data software operation
  • Internet Ready
    • Iridium Satellite
    • Cellular: CDMA, DoCoMo, Worldwide GSM

Specifications
Description
Instrument type 15 channel internet-enabled wind energy data logger
Applications wind resource assessment
Sensor compatibility - counter channels
  • NRG #40C anemometer
  • opto anemometer
  • reed switch anemometer
  • rain gauge
Sensor compatibility - analog channels
  • NRG 200P direction vane
  • NRG 110S temperature
  • Li-Cor 200SA pyranometer
  • NRG BP-20 absolute pressure (requires optional iPack power)
  • RH-5 relative humidity (requires optional iPack power)
Counter channels

Channels 1-6 and 13-15 are counter inputs:

  • channels 1-3 and 13-15 are pre-programmed for NRG #40C anemometers or compatible sensors
  • channels 4-6 use counter Signal Conditioning Modules (SCMs) to configure the channels for other sensors
Analog channels

Channels 7-12 are analog inputs:

  • channels 7 and 8 are dedicated for NRG 200P direction vane
  • channels 9-12 use analog Signal Conditioning Modules (SCMs) to configure the channels for other sensors
Data Collection
Sampling interval 2 seconds
Averaging interval 10 minute, fixed
Real time clock internal battery-backed
Storage medium 32 MB MultiMedia Card (MMC), non-volatile FLASH
Maximum data storage 664 days
Parameters recorded for each channel
  • each 10 minute interval is time/date-stamped
  • average
  • standard deviation
  • min*
  • max* *min and max not used for wind direction vanes
File format
  • Windows compatible
  • (1) 14 KB binary file per day
  • header includes site, serial number and sensor information
Software

Symphonie Data Retriever for Windows (included)

  • scales raw data
  • creates measurement database for each site
  • creates basic reports
  • maintains site and sensor information
  • configures iPacks
Reader Windows compatible MMC reader accesses data stored on MMC
Data delivery MMC cards, and/or internet email via optional iPack:
GSM, CDMA (Verizon or Telus) and Iridium Satellite
Resolution
Analog measurement resolution 0.1% of full scale (1024 counts)
Counter average stored resolution 0.1% of the value stored
Analog average stored resolution 0.1% of the value stored
Min / Max stored resolution 0.4% of the value stored
Standard deviation stored resolution 4% of the value stored
Configuration
User interface
  • Liquid Crystal Display (LCD) 4 x 20 characters
  • 16 key pad (6 navigation keys plus numeric/phone pad) with audible feedback
Configurable parameters
  • clock
  • time zone
  • site number
  • display scaling (defaults are provided for each channel based on channel type)
iPack options
  • iPack configured via serial port connection to your PC
  • serial connection direct to iPack or through logger's iPack access port
  • Symphonie Data Retriever for Windows integrates iPack settings
Connections
Sensor wiring
  • sensors connect to removeable field wiring panel
  • ground stud connects to earth ground with included ground cable
  • male DB25 interfaces to one optional iPack communications module
  • iPack access port facilitates field programming and accepts headset for voice calls
  • 3 SCM slots for counter channels 4, 5, 6
  • 4 SCM slots for analog channels 9, 10, 11, 12
Power requirements
Batteries
  • (2) 1.5 Volt D-Cell Batteries (included)
  • nominal voltage: 1.5 Volts
  • minimum voltage: 0.9 Volts
  • battery life approximately one year, depending on configuration
External power input provided by an optional iPack
External solar input Other
  • provided by an optional iPack
  • optional iPacks provide 12V power (20mA max.)
  • PV/Battery only iPack provides power to sensors and logger for stand alone configurations
Installation
Mounting
  • mounts with 4 bolts (included) to keyed slots inside of metal shelter box
  • shelter box mounts to tower with hose clamps
Tools required
  • screwdriver for input terminals, included
  • 8 mm (5/16 inch) wrench or nut driver for logger mounting screws
  • 3/8 inch wrench or nut driver for logger ground nuts
Environmental
Operating temperature range -40°C to 65°C (-40°F to 149°F)
Note: display readable -30°C to 55°C (-22°F to 130°F)
Operating humidity range 0 to 100% RH non-condensing
Lifespan 10 years +
Physical
Weight 1.3 kg (2.6 pounds), including batteries
Dimensions 22.2 cm (8.7”) h x 18.8 cm (7.4”) w x 7.7 cm (3.0”) d, including field wiring panel
Materials
Faceplate injection molded black ABS
Buttons white elastomer dome keypad
Wiring panel fiberglass-epoxy terminal board, sealed gold plated pins, zinc plated screws and terminals
Enclosure

Weatherproof polycarbonate, meets the following specifications:

  • NEMA type 4, 4X and 13
  • IEC: IP65

Order Information
Cat. No. Description
4289 SymphoniePLUS 15-channel data logger

 

 

Convertisseur d'unités