Shopping Cart

0 item(s) - 0.00$
Your shopping cart is empty!
 
Drop us a line
Contact
 
T: 514-354-2511
T: 1 800 463-4363
F: 514-354-6948
Portable Samplers Environment

Portable Samplers 24 bottles from Hach

Product Code:900MAX


Need more Info? (514) 354-2511 - 1-800-463-4363

The Hach Sigma 900MAX Portable Sampler’s advanced technology and comprehensive customer service can be summarized in five key concepts: accuracy, simplicity, flexibility, reliability, and economy.

Easy, menu-type programming uses a large backlit display. Use the Hach Sigma 900MAX sampler to monitor and log rainfall, level, flow, velocity, temperature, pH or ORP, with 12 data logging channels. Depending on model, up to seven external analog signals can also be logged. As many as 116,000 readings may be recorded.

Unique Constant Time / Variable Volume Sampling

The patented Constant Time/Variable Volume sampling method varies sample size in proportion to flow rate. This feature takes regularly timed, proportional samples depending on the flow rate, ensuring that representative samples are taken at even intervals throughout the sampling period.

Field Convertible for Compact or Discrete Sampling

Weighing only 28 pounds (12.7 kg), the 900MAX Portable Sampler is designed for accuracy and convenience. Quickly switch between composite and discrete sampling in the field. Configurable for single- or multiple-bottle applications, it is specifically designed for use in 18-inch manholes.

Reliable Peristaltic Pump Technology

The 900MAX sampler uses a positive displacement peristaltic pump made of corrosion-resistant Delrin® material. While other peristaltic pumps fail to meet EPA1 criteria for representative intake velocity, Hach samplers produce a 3.3 ft./s velocity at3 ft. lift in a 3/8-in. ID intake line.

Advanced Liquid Detection Techniques

The non-contact ultrasonic liquid sensing system guarantees volume accuracy and repeatability. Reduce cross-contamination with a line rinse; the intake is preconditioned with the source liquid prior to collection. In the event that a plugged intake prevents collection, the unit detects the failed attempt and immediately repeats the cycle starting with a high-pressure purge.

Customizable Set Points

Collect samples in response to changing levels of selected parameters—set high and low trip points to immediately collect when a parameter exceeds preset limits.

Easy Data Management Software

Powerful, user-friendly software makes it easy to analyze the data and produce presentation-quality reports for any time period, or generate customized reports integrating sample collections with a variety of parameters.
 

Specifications
General
Sampler Housing
  • Impact resistant ABS plastic, 3-section construction
  • Double-walled base with 1 in. (2.54 cm) insulation, direct ice contact with bottles
Controller Housing High-Impact, injection-molded ABS; submersible, watertight, dust-tight,
corrosion, and ice resistant; NEMA 4X, 6
Temperature
  • General Use: 0 to 49 °C (32 to 120°F)
  • Liquid Crystal Display (LCD): -10 to 70°C (-14 to 158°F)
  • Storage: -40 to 80°C (-40 to 176°F)
Power Requirements
  • 12 Vdc supplied by optional a/c power converter or battery.
    Average current with pump running: 2.25 amps dc
  • Certification: CSA, UL, CE
ac Power Backup
(Pump Controller Only)
  • Rechargeable 6 amp-hour gel lead acid battery takes over automatically with ac line power failure
  • Integral trickle charger maintains battery as full charge (factory installed option)
Solar Power
Panel/Backup
12 Vdc regulated supply voltage, 5 watts minimum; optional 12 Vdc lead-acid or gel-electrolyte battery backup
Internal Battery Two 1.5 V dc “C” cells; maintains program logic and real time clock for five years
Graphics Display
  • 8 line x 40 character alphanumeric, back-lit liquid-crystal graphics display
  • Self prompting/menu driven program
User Interface 21 key membrane switch keypad with 4 multiple function soft keys
Data Logging
  • Records program start time and date, sample volume collected, sample volume remaining. Stores up to 400 sample collection times/dates, all program entries, operational status.
  • Up to 200 events logged, including alarm conditions, program run/stop events, etc.
Set Point
Sample Trigger
When equipped with integral flow meter or pH/temperature/ORP meter options, sampling can be triggered by an upset condition when fieldselectable limits are exceeded.
Sampling Modes Multiple bottle time, multiple bottle flow, composite time, composite flow, composite multiple bottle time, composite multiple bottle flow, flow with time override, variable interval, start/stop, and level actuation
Overload Protection 5 amp dc line fuse for pump; 5 amp dc line fuse for ac power converter
Diagnostics Tests keypad, RAM, ROM, pump, distributor, liquid sensor, and velocity signal
Program Languages Czech, Danish, Dutch, English, French, German, Spanish, Swedish
Program Lock Access code protection prevents tampering
Dimensions
  • Standard and 12 Bottle Base: 50.5 cm x 69.4 cm (10.9 x 27.3 in.)
  • Compact Base: 44.1 x 61 cm (17.4 x 24 in.)
  • Composite Base: 50.28 x 79.75 cm (19.8 x 31.4 in.)
Weight
  • Standard and 12 bottle base: 15 kg (35.6 lb.) with (24) 1-L polyethylene bottles 14.8 kg (32.6 lb.) with 3-gal polyethylene container
  • Compact Base: 12.2 kg (27 lb.) with (24) 575-mL polyethylene bottles 12.9 kg (28.3 lb.) with 3-gal polyethylene container
  • Composite Base: 15 kg (36 lb.) with (12) 950-mL glass bottles
Communications
EPROM Flash Memory Via RS232; permits embedded software upgrades in the field; requires ac power
Serial Interface RS-232 compatible; allows on-site collection of stored data
Program Delay
  • 1 to 9,999 minutes or external flow pulses in one unit increments
  • Sampler start time/date and time/day
  • Sampler start on external 12 Volt or contact closure input
Sample Bottle Capacity
Standard Base Capacity
  • (24) 1 L polyethylene and/or 350-mL glass bottles
  • (8) 2.3 L polyethylene and/o 1.9 L glass bottles
  • (4) 3.8 L (1 gal) polyethylene and/or
  • (4) 3.8 L (1 gal) glass bottles
  • (2) 3.8 L (1 gal) polyethylene and/or
  • (2) 3.8 L (1 gal) glass bottles
  • 20.8 L (5.5 gal) polyethylene composite container or (1) 15.1 L (4 gal) polyethylene composite container or (1) 20 L (6 gal) polyethylene or (1) 10 L (3 gal) polyethylene or (1) 9.5 L (2.5 gal) glass
Compact Base Capacity
  • (24) 575 mL polyethylene bottles
  • (8) 950 mL glass bottles
  • 11.4 L (3 gal) polyethylene bottle
  • 9.5 L (2.5 gal) glass bottle
12 Bottle Base Capacity
  • (12) 950 mL glass bottles
  • 10 L (3 gal) polyethylene bottle
  • 9.5 L (2.5 gal) glass bottle
Composite Base
Capacity
22.7 L (6 gal) polyethylene bottle
Ice Capacity
  • Compact Base: 3.9 kg (8.5 lb.) with (24) 575 mL PE bottles
  • Standard Base: 14.5 kg (32 lb.) with (24) 350 mL glass bottles
Sampling Features
Multiple Programs Stores up to five sampling programs
Cascade Allows use of two samplers in combination; at the completion of its program, the first sampler initiates the second
Upset Sampling When equipped with integral flow meter or pH/temperature/ORP monitoring options, or triggered from an external control device, sampling can be started in an upset condition when field-selectable limits are exceeded. Concurrent with normal sampling routine, sample liquid is deposited in designated “Trouble Bottle(s)”
Status Display Alerts operator to low main battery, low memory battery, plugged intake, jammed distributor arm, sample collected, and purge failure
Automatic Shutdown
  • Multiple Bottle Mode: After complete revolution of distributor arm
    (unless Continuous Mode is selected)
  • Composite Mode: After preset number of samples have been delivered to composite container, from 1 to 999 samples, or upon full container.
Sample Volume Programmed in one mL increments from 10 to 9,999 mL
Sample Volume
Repeatability
±5% typical
Interval Between Samples Selectable in single increments from 1 to 9,999 flow pulses (momentary contact closure 25 ms or 5 to 12 Vdc pulse; 4-20 mA interface optional), or 1 to 9,999 minutes in one minute increments
Multiplex (Multiple Bottle Mode) Programming allows multiple samples per bottle and/or multiple bottles per sample collection
Sample Pump and Strainer
Sample Pump High-speed peristaltic, dual roller, with 0.95 ID x 0.16 OD cm 3/8 ID x 5/8 in. OD) pump tube
Pump Body Impact/corrosion resistant, glass reinforced Delrin®
Vertical Lift 8.23 m (27 ft.) maximum
Note: Remote Pump Option recommended for lifts from 6.7 to 10.7 m (22 to 35 ft.)
Sample Transport Velocity 0.61 cm/s (2 ft./s) minimum,  at 4.6 m (15 ft.) vertical lift in a 0.95 cm (3/8-in.) ID intake tube
Pump Flow Rate 60 mL/s at 0.91 m (3 ft.) vertical lift in a 0.95 cm (3/8-in.) ID intake line
Liquid Sensor Non-wetted, non-contact, ultrasonic
Intake Purge Air purged automatically before and after each sample; duration automatically compensates for varying intake line lengths
Pump/Controller Housing High impact injection molded ABS;  submersible, watertight, dust tight, corrosion and ice resistant; NEMA 4X, 6
Internal Clock Indicates real time and date; 0.007% time base accuracy
Manual Sample Initiates a sample collection independent of program in progress
Intake Rinse Intake line automatically rinsed with source liquid prior to each sample, from 1 to 3 rinses
Intake Retries Sample collection cycle automatically repeated from 1 to 3 times if sample not obtained on initial attempt
Intake Tubing 9.5 mm (3/8 in.) ID vinyl or 9.5 mm (3/8 in.) ID Teflon® lined polyethylene
Intake Strainers Choice of Teflon® and 316 stainless steel construction, or all 316 stainless steel in standard size, high velocity, and low profile for shallow depth applications
Factory-Installed Options
pH/TEMPERATURE/ORP METER
Control/Logging Field selectable to log pH/temperature or ORP independent of sample operation or to control sample collection in response to exceeding setpoints
pH/Temperature Sensor
  • Temperature compensated; impact resistant ABS plastic body
  • Combination electrode with porous Teflon® junction
Measurement Range
  • pH: 2 to 12 pH
  • Temperature: -10 to 105°C (-14 to 221°F)
Operating Temperature -18 to 80°C (0 to 176°F)
Dimensions 1.9 x 15.2 cm (0.75 x 6 in.) with 1.9 cm (0.75 in.) MPT cable end
SUBMERGED PRESSURE TRANSDUCER
Material Epoxy body with stainless steel diaphragm
Cable
  • Polyurethane sensor cable with air vent
  • Length: 7.6 m (25 ft.) standard; 20 m (15.24 ft.) optional
Sensor Dimensions 2 x 3.8 x 12.7 cm (0.8 x 1.5 x 5 in.)
Maximum Range 2.5 psi, 0 to 1.75 mm (0 to 5.76 ft.)
Maximum Allowable Level 3x over pressure
Operating Temperature 0 to 71°C (32 to 160°F)
Compensated Temperature Range 0 to 30°C (32 to 86°F)
Air Intake Atmospheric pressure reference is desiccant protected
Factory-Installed Options (continued)
SUBMERGED DEPTH/VELOCITY PROBE
Velocity Measurement
Range -1.52 to 6.10 m/s (-5 to 20 ft./s)
Zero Stability 0.015 m/s (<0.05 ft./s)
Accuracy ±2% of reading
Operating Temperature -18 to 60°C (0 to 140°F)
Typical Depth 2 cm (0.8 in.) minimum for velocity
Method Doppler ultrasonic
Transducer Type Twin 1 MHz piezoelectric crystals
Level Measurement
Range
  • Standard: 0 to 3 m (0 to 10 ft.)
  • Extended: 0 to 9 m (0 to 30 ft.)
Accuracy
  • ±0.16% full scale ±1.5% of reading at constant temp (±2.5 °C)
  • ±0.20% full scale ±1.75% of reading from 0 to 30 °C (32 to 86 °F)
  • ±0.25% full scale ±2.1% of reading from 0 to 70 °C (32 to 160 °F)
Allowable Level
  • Standard: 10.5 m (34.5 ft.) maximum
  • Extended: 31.5 m (103.5 ft.) maximum
Air Intake Atmospheric pressure reference is desiccant protected
Method Pressure transducer with stainless steel diaphragm
General
Material Noryl® plastic outer shell with epoxy potting
Power Consumption ~1.2 W at 12 Vdc
Cable Urethane sensor cable with air vent
Connector Hard anodized (satisfies Military Spec 5015)
Cable Length
  • Standard: 9, 15, 23, and 30.5 m (30, 50, 75 and 100 ft.)
  • Custom: greater than 30.5 m (100 ft.)
  • Maximum: 76 m (250 ft.)
Cable Diameter 0.91 cm (0.36 in.)
Sensor Dimensions 2.3 x 3.8 x 13.5 cm (0.9 x 1.5 x 5.3 in.)

 

Dimensions
The Hach Sigma 900MAX Portable Sampler is designed for indoor or outdoor use. No secondary enclosure is required when operated within the specified temperature range. The sampler consists of three main sections—the top cover, the center control system, and the bottle/base section held together by stainless steel latches which serve as the connection point for the optional suspension harness. The lockable top cover protects the controller from extreme weather and unauthorized use.

 

Specifications
Sigma 900MAX Portable Sampler Bundles
6249300 900MAX Portable pH Bundle, with 3 gallon bottle
6249400 900MAX Portable pH Bundle, with 6 gallon bottle
6249500 900MAX Portable pH Bundle, with (8) 2.3 liter bottles
6249600 900MAX Portable pH Bundle, with (24) 575 liter bottles
Controller and Base Options
8930 Sigma 900MAX Portable Sampler, with controller, center sections, and top cover
(complete sampler requires adding a base option)
8975 Compact Insulated Base
8976 Standard Insulated Base
8958 12 Bottle Base
8561 Composite Insulated Base
Bottle Options
6559 2.5 Gallon Glass, with Teflon-lined cap
1918 3 Gallon Polyethylene, with cap
6494 6 Gallon Polyethylene, with cap
1502 1502 Container Support
8996 Retainer/Full Container Shut-off
737 Set of (24) 1 Liter Polyethylene, with caps
1369 Set of (24) 575 mL Polyethylene, with caps
2348 Set of (8) 950 mL Glass, with Teflon lined caps
2217 Set of (4) 1 Gallon Polyethylene, with caps
2216 Set of (4) 1 Gallon Glass, with Teflon lined caps
2215 Set of (2) 1 Gallon Polyethylene, with caps
2214 Set of (2) 1 Gallon Glass, with Teflon lined caps
Bottle Retainers (for multiple bottles)
2620 Retainer for (12) 950 mL Glass Bottles
2189 Retainer for (24) 350 mL Glass Bottles
1422 Retainer for (8) Glass, (8) Poly, (24) 575 mL Poly, and (24) 1 Liter Poly Bottles
2347 Retainer for (8) 950 mL Glass Bottles
2190 Retainer for 1 Gallon Glass and 1 Gallon Polyethylene Bottles
Distributors
8582 Distributor with Arm for 24 Bottle, Standard Case and 12 Bottle Base
8580 Distributor with Arm for 24 Bottle Compact Base
8584 Distributor with Arm for 2, 4 and 8 Bottle Standard Base and 8 Bottle Compact Base
8583 Distributor Arm only for 24 Bottle Standard Base and 12 Bottle Base, requires distributor assembly
8581 Distributor Arm for 24 Bottle with Compact Base, requires distributor assembly
8585 Distributor Arm for 2, 4 and 8 Bottle with Standard Base, requires distributor assembly
Intake Tubing and Strainers
922 25 ft. Teflon Lined Polyethylene Tubing, 3/8-in. ID (requires Prod. No. 2186 Connection Kit)
2186 Connector Kit, for Teflon lined polyethylene tubing 920 25 ft. Vinyl Intake Tubing, 3/8-in ID
2070 Strainer, all 316 stainless steel
2071 Strainer, for shallow depth applications, all 316 stainless steel
4652 Strainer, high velocity and shallow depth
Pump Tubing
460015 Pump Tubing, 15 ft.
8964 Pump Tube Insert
Integral Water Quality Parameters
8793 Integral pH-Temp/ORP Option, factory installed
3328 pH-Temperature Probe (grounded), with 25 ft. cable
5172 pH-Temperature Probe; grounded, with 50 ft. cable
2080 ORP Probe; with 25 ft. cable
5174 ORP Probe; with 50 ft. cable
4-20 mA Input
8795 Three (3) Analog Input Data Logging Channels
4-20 mA Output
8797 First 4-20 mA Output
8798 Second 4-20 mA Output

 

Convertisseur d'unités