Calibration Check™ pH/ORP Meter Biotechnology

Calibration Check™ pH/ORP Meter

Product Code:HI9126

Need more Info? (514) 354-2511 - 1-800-463-4363

The HI 9126 is the next generation in professional, accurate, easy-to-use pH meters. Designed to provide laboratory results in a sleek, portable design. The HI 9126 features HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH bulb, Calibration Check™ prompts the user that additional cleaning may be needed.

The extended multi-level LCD displays pH and temperature (°C or °F) readings simultaneously, while also displaying the electrode status and operational guides. The HI 9126 helps users through the calibration process with clear on-screen messages. The meter features a series of diagnostic features to improve measurement consistency and reliability.

Calibration is performed automatically at 1 or 2 points with 7 standard buffers and 2 custom buffers. HI 9126 is supplied with rechargeable batteries and a inductive docking station for easy recharging. The meter is provided with the BEPS (Battery Error Prevention System) which automatically turns the instrument off when the battery level is too low to ensure reliable readings.
The HI 9126 can also be used for ORP measurements in the mV range with 0.1 mV resolution.

  • Exclusive Calibration Check™ (HI 9126)
  • Electrode condition monitoring (HI 9126)
  • Backlit LCD (HI 9126)
  • Multi-level display
  • On-screen operational guide
  • Extended pH and temperature ranges
  • Up to 7 standard buffers for calibration and 2 custom buffers
  • User-selectable calibration timeout reminder
  • Measures in °C or °F
  • Waterproof
  • Rechargeable batteries
  • Inductive battery recharger docking station included
  • BEPS (Battery Error Prevention System)
  • pH electrode, temperature probe and hard carrying case included




Order Information
Cat. No. Description
HI 9126, HI 9125 and HI 9124 are supplied with HI 1230B combination double-junction, gel-filled pH electrode, HI 7662 stainless steel temperature probe with 1 m (3.3’’) cable, pH 4.01 & pH 7.01 buffer solutions (20 mL sachets), 100 mL plastic beaker, (4) 1.2 AAA rechargeable batteries (inside the instrument), HI 710044 inductive recharger* with power adapter, instruction manual and rugged carrying case.
* HI 9126-01 (115V), HI 9126-02 (230V), HI 9125-01 (115V), HI 9125-02 (230V), HI 9124-01 (115V), HI 9124-02 (230V)
HI 1230B pH electrode, double junction, PEI body, BNC connector, 1 m (3.3’) cable
HI 3230B ORP electrode, gel filled, PEI body, with platinum sensor, BNC connector, 1 m (3.3’) cable
HI 7662 Temperature probe
HI 7004L pH 4.01 buffer solution, 500 mL
HI 7007L pH 7.01 buffer solution, 500 mL
HI 7010L pH 10.01 buffer solution, 500 mL
HI 70004P pH 4.01 buffer solution, 20 mL sachets (25)
HI 70007P pH 7.01 buffer solution, 20 mL sachets (25)
HI 70010P pH 10.01 buffer solution, 20 mL sachets (25)
HI 70300L Electrode storage solution, 500 mL
HI 7061L Electrode cleaning solution, 500 mL
HI 76405 Electrode holder


Convertisseur d'unités