Shopping Cart

0 item(s) - 0.00$
Your shopping cart is empty!
 
Drop us a line
Contact
 
T: 514-354-2511
T: 1 800 463-4363
F: 514-354-6948
Solvent cleaner Material Testing

Solvent cleaner

Product Code:LENIUM RV


Need more Info? (514) 354-2511 - 1-800-463-4363

Description
LENIUM RV is a stabilized normal Propyl Bromide (n-PB) formulation specially designed to remove contaminants such as bituminous cement, oils, and greases. The fluid has physical properties and solvency characteristics that are similar to chlorinated solvents such as 1,1,1-trichloroethane (TCA) and trichloroethylene (TCE).

LENIUM RV is an ideal replacement for 1,1,1-trichloroethane, trichloroethylene, and methylene chloride used in tests for Asphalt Content Extraction (ASTM D2172), Recovery of Extracted Binder (Abson-ASTM D1856; Rotavapor ASTM D5404), or combined extraction and recovery methods (AASHTO T 319-031).

 

Typical Properties
The physical and environmental properties of LENIUM RV are compared to other chlorinated solvents in Table 1.
Table 1
  LENIUM RV Trichloroethylene Methylene
Chloride
1,1,1-TCA
Flash Point (TCC) None None None None
Boiling Point 160°F (71°C) 189°F (87°C) 104°F (40°C) 165°F (74°C)
Specific Gravity @ 25°C 1.35 1.46 1.33 1.32
Viscosity @ 25°C 0.49 cp 0.54 cp 0.43 cp 0.79 cp
Surface Tension (dynes/cm) 25.9 26.4 28.2 25.6
Vapor Pressure @ 20°C 110.8 mm Hg 57.8 mm Hg 349 mm Hg 100 mm Hg
Evaporation Rate (TCA = 1) 0.96 0.57 1.64 1
Specific Heat @ 25°C 0.27 0.22 0.28 0.25
Heat of Vaporization 58.8 cal/g 57.2 cal/g 78.7 cal/g 57.5 cal/g
Solubility in Water 240 ppm 110 ppm 140 ppm 70 ppm
Solubility of Water 500 ppm 300 ppm 6 ppm 500 ppm
Flammability Limits (vol %) 4 ñ 7.8 8 ñ 10.5 14 ñ 22 7 ñ 13
Kauri Butanol (KB) Value 125 129 136 124
Atmospheric Lifetime 16 days <1 year <1 year 5 years
ACGIH TLV 25 ppm * 50 ppm 25 ppm 350 ppm
* manufacturer recommended

 

 

Environmental and Regulatory
Table 2
Ozone Depletion Potential (ODP) 0.013 – 0.018*
Global Warming Potential (GWP) Zero
Volatile Organic Compound (VOC) Yes
Significant New Alternatives Program (SNAP) Pending
Hazardous Air Pollutants (HAP) No
National Emission Standards for Hazardous Air Pollutants (NESHAP) Not regulated
Superfund Amendments and Reauthorization Act (SARA Not regulated
Resource Conservation and Recovery Act (RCRA) Not regulated
* Source: US EPA. ODP may be greater at locations near the equator.

 

 

Disposal

Petroferm recommends contacting your current or local environmental service company for disposal of this product. The most common and economical method of disposal is incineration of used material in compliance with all applicable government regulations. Used LENIUM RV can also be delivered to a solvent reclaimer.

 

 

Packaging

LENIUM RV is available in 5-gallon pails (55 lb) and 55-gallon drums (600 lb). Samples are available in one-quart containers upon request.

 

 

Storage

LENIUM RV should be stored in the original container, preferably in a cool, ventilated, fire-resistant building. Avoid overheating or freezing.

 

 

Shelf Life

The shelf life for this product is indefinite when it is stored in its original, sealed container at room temperature. However, the product should be inspected after the designated date on the product label (twenty-four months from the date of manufacture) prior to customer use.

 

 

Convertisseur d'unités