Sonde pour profilage d'humidité et température Gropoint Profile

Sonde pour profilage d'humidité et température

Fabricant :GroPoint
Modèle :Profile
1 355,00$ 1 275,00$


Besoin de plus d'informations? (514) 354-2511 - 1-800-463-4363

GroPoint™ Profile provides cost-effective measurement of volumetric water content over multiple depths using a single probe, eliminating the cumbersome excavation required for multiple sensors placed at different depths.

It can be deployed in irrigation-sensitive zones to enable full control of precision irrigation needs, providing an understanding of water movement through the soil.

The sleek, lightweight design installs quickly with minimal soil disruption using a pilot rod and slide hammer tool. Designed for vertical installation, the sensor takes measurements over multiple soil layers, with each measurement zone (segment) providing the average volumetric soil moisture content over a 15 cm range (approximately 6 inches).

 

The Most Accurate and Cost-Effective Soil Profiling Solution Available

  • Eliminates need for multiple sensors and cabling systems.
  • Installs quickly and easily without excavating.
  • One SDI-12 address is used to read all segments, providing for simplified installations. Optional RS-485 output.
  • Moisture readings can be user-calibrated with 3rd-order polynomials to meet custom requirements.
  • Low power requirements—suitable for remote, autonomous applications.
  • Patented TDT5 technology for scientific-grade accuracy and excellent long-term stability of measurements.
  • Fully potted electronics for excellent durability.

 

Moisture  
Measurement range 0% to 100% of VMC
Accuracy ±1.0% *
Precision < 0.2%
Temperature  
Measurement range -20°C to +70°C (-4°F to 158°F)
Accuracy ±0.5°C
Electrical  
Output SDI-12 V1.3 (RS485 optional)
Connection Bare wire (optional 4 pin, IP66/IP68 rated environmental connector)
Input voltage 6 to 14 VDC max. 18 VDC
Current consumption Quiescent: <0.5mA
Active: 15-20 mA (depending on number of segments) for 100 mS
Warm-up time on power up < 1 second
Environmental  
Operating temperature -20°C to 70°C (-4°F to 158°F)
Storage temperature -40°C to 85°C (-40°F to 185°F)
Physical  
Length Each segment is approximately 15 cm (5.9") long. Total length is the number of segments multiplied by 15 cm. For example, a 3-segment probe is about 45cm long.
Probe weight 2 segments: 292 g (10.3 oz.)
3 segments: 351 g (12.4 oz.)
4 segments: 408 g (14.4 oz.)
5 segments: 468 g (16.5 oz.)
6 segments: 526 g (18.6 oz.)
8 segments: 642 g (22.6 oz.)
Cable weight 38 g per m (0.42 oz. per foot)
Standard cable 5 m (16.3 ft.)
4xAWG22 dual-shielded, twisted pair, rated for direct burial
Warranty 1-year limited parts and labour