Votre panier est vide !
 
Pour nous joindre
Contact
Moniteur d'ozone série 200

Moniteur d'ozone série 200

Modèle :Série 200


Besoin de plus d'informations? (514) 354-2511 - 1-800-463-4363

Specification
Series 200 Monitor Base
Measurement units ppm
Removable / replaceable sensor head Yes
On-board alarm No
Alarm status displayed No
Low battery indication Yes
Alarm mute function No
Sensor condition status Yes
Stand-by mode Yes
External signal for alarms & control None
External signal functions None
Analogue output None
Power supply 12 VDC, 800 mA
Rechargeable battery pack (2 x options) Standard 9.6V ( 940mA/hr Ni-Cd)
  Long Life 9.6V (2100mA/hr Ni-MH )
Portable Yes
Permanently fixable Screw fix
Remote Sensor Capability Yes
Enclosure rating IP20 & NEMA 1 equivalent
Size (with sensor head) 195 x 122 x 54 (mm); 7> x 43/4 x 2@ (in)
Weight (with sensor head and battery) < 460 g; < 16 oz
Approvals Part 15 of FCC Rules
EN 50082-1: 1997
EN50081-1: 1992

 

Ozone Sensor Head Specifications
Sensor Heads Low High Leak
Measurement range 0.000 - 0.500 ppm 0.50 - 20.00 ppm 0.00 - 50.00 ppm
Accuracy < 0.008 ppm (0 - 0.100 ppm)
± 10% (0.100 – 0.500 ppm)
± 10% (0.20 - 2.00 ppm)
± 15% (2.00 - 20.00 ppm)
± 20%,
15 seconds after Reset

Resolution

0.001 ppm 0.01 ppm 0.01 ppm
Controlled Atmosphere Version Available on Request Available on Request Available on Request
T90 Response < 60 seconds (T90) < 35 seconds (T90) < 10 seconds
Sensor type Gas-sensitive semiconductor
Operating temperature range -5°C to 50°C; 23°F to 122°F (sensor head and base unit)
Relative humidity limit 95% maximum (sensor head and base unit)

 

 

VOC Sensor Head Specification*
Measurement range 0 to 400 ppm toluene
Accuracy < +/- 10 ppm (0 – 200 ppm)
< +/- 10% ( > 200 ppm)
T90 response < 60 s
Sensor type Gas-sensitive semiconductor
Operating temperature range -20°C to 60°C
Operating relative humidity range 5 to 95% non-condensating
* Specific Calibrations to other VOC’s available – contact Aeroqual Sales
Ammonia Sensor Head Specification
Measurement range 0 to 1000 ppm
Accuracy < +/- 5 ppm (0 – 100 ppm) < +/- 10% (100 – 1000 ppm)
T90 response < 60 s
Sensor type Gas-sensitive semiconductor
Operating temperature range -20°C to 60°C;
Operating relative humidity range 5 to 95% non-condensating
CO Sensor Head Specification
Measurement range 0 to 2000 ppm carbon monoxide
Accuracy < +/- 10 ppm in the range 0 to 400 ppm
T90 response < 150s
Sensor type Gas-sensitive semiconductor
Operating temperature range 0°C to 70°C;
Operating relative humidity range 5 to 95% non-condensating
Approvals UL 2034, BS 7860

 

 