Votre panier est vide !
 
Pour nous joindre
Contact
Détecteur de fuite de refrigérant et de gaz combustibes

Détecteur de fuite de refrigérant et de gaz combustibes

Modèle :Informant 2™


Besoin de plus d'informations? (514) 354-2511 - 1-800-463-4363

The new Informant 2 - the only dual-purpose, refrigerant/combustibles leak detector on the market - is also the fastest, most precise leak detector available. Its powerful combination of advanced sensor technology, microprocessor-controlled circuitry and state-of-the-art software design offers unsurpassed accuracy and reliability with astonishing speed - identifying either refrigerant or combustible leak sources in 2/10 of a second. 

The Informant 2 utilizes a unique Bacharach-developed heated diode sensor and features an automatic sensitivity adjustment so it is quickly responsive to all types of refrigerant. It also detects all combustible gases with a 50 ppm minimum. It includes an audible leak indicator with mute option, as well as dual bar graph displays and a flashing probe tip for visual confirmation. Plus, The Informant 2's lightweight, ergonomic design and flexible two-position probe with tapered probe end make finding hard-to-reach leak sources easy. The Informant 2 comes complete with a soft-sided carrying pouch that can be attached to the waist for easy portability. For added protection, an optional rubber boot with a MagLitel flashlight cavity is available to facilitate one-handed inspections.

FEATURES
  • Microprocessor-controlled circuitry for guaranteed greater accuracy and reliability
  • Identifies leak sources in just 2/10 of a second
  • Automatic sensitivity adjustment via the microprocessor, even when high levels of background vapors or refrigerants are present
  • Detects scores of hydrocarbon gases
  • Interchangeable sensor tips that can be swapped out in seconds
  • Easy-to-clean hydrophobic filter that prevents water from reaching the sensor tip
  • Ergonomically designed and lightweight for easy operation
  • Tapered probe end for easy access to hard to reach areas
  • Flashing probe tip with variable frequencies to indicate changing gas concentrations
  • Audible indicator with mute feature
  • Sensor fail indication
  • Dual bar graph displays that offer visual confirmation no matter what position the instrument is in
  • LED indicating when power is on, the amount of battery life left, and when the mute feature is activated
  • Single probe with 20" maximum length that can also be wrapped around the instrument for a 3" probe
  • Optional rubber boot with MagLitel flashlight cavity for easy one handed inspections and added protection
  • Powered by 4 "AA" disposable alkaline batteries
  • Meets or exceeds SAE J1 627 for RI 34a, R1 2 and R22
  • Will locate many halogens in CFC, HCFC, HFC and blends

 

SPECIFICATIONS
Sensing Elements:
Refrigerant
Combustible
-
• Heated Diode, U.S. Patent No. 5,932,176
• Patented semiconductor type, 5 year
  typical life, plug-in replacement
Refrigerants Detected • All CFC, HCFC and HFC refrigerants including: R-12, R-22, R-123, R-134a and blends R-404A, R-408A, R-409A and R-410A (i.e., any refrigerant containing Chlorine, Fluorine or Bromine gas)
Combustible Gases Detected • All combustible gases and vapors
Alarm Sensitivity:
Refrigerant
Combustibles
• 0.25 oz/year of R134a (hardest to detect refrigerant)
• Minimum 50 PPM (Methane)
Alarm Types • Audible and dual visual LEDs
Power Source • Four (4) AA disposable alkaline batteries included
Warm-up Time • 10 seconds
Response Time:
Refrigerant
Combustible
• 2/10 second
• 2/10 second
Battery Life - 4 to 5 hours, under typical intermittent operation.
Probe - 20" (50.8 cm) maximum length, fully extended; 3" (7.62 cm) if wrapped around instrument. Includes LED indicator
Size - 1.75"W (4.44cm) x 9.62"L (24.43cm) x 2.25"H (5.72 cm)
Weight - 0.86 lbs. (0.39 kg) with batteries
Agency Approvals:
Refrigerant
Combustible
-
• UL listed in accordance with SAE J1627
• MET Lab certified to UL 913, intrinsically safe for use
  in Class I, Division 1, Group D hazardous areas.
CE-Mark • Independently tested
Warranty •1 year, including sensors

 

APPLICATIONS
Because the Informant 2 detects either refrigerant or combustible leaks, the instrument can be used for leak detection in air-conditioning units or refrigeration systems as well as residential, commercial and industrial appliances/equipment. It can also be used to inspect gas lines, gas valves, regulators and meters on gas equipment. Professionals who would benefit from using The Informant 2 include HVAC service technicians, mechanical contractors, refrigeration manufacturers, gas utility personnel, plant maintenance personnel, environmental chamber manufacturers, and automotive service technicians.

 

CAT. NO. DESCRIPTION
19-8042 DUAL Refrigerant/Combustible Informant 2 Detector Kit. Instrument comes with refrigerant and combustible gas sensors, color-coded sensor tips, instruction manual, 4 AA batteries, 5 filters, custom soft carrying case and one container of refrigerant check gas.
19-8045 DUAL Deluxe Refrigerant/Combustible Informant 2 Detector Kit. Instrument comes with refrigerant and combustible gas sensors, color-coded sensor tips, protective rubber boot, MagLite®, instruction manual, 6 AA batteries, 5 filters, custom soft carrying case and one container of refrigerant check gas all packaged in a hard carrying case.
19-8040 REFRIGERANT ONLY Informant 2 Detector Kit. Instrument comes with refrigerant sensor, color-coded sensor tip, instruction manual, 4 AA batteries, 5 filters, custom soft carrying case and one container of refrigerant check gas.
19-8043 REFRIGERANT ONLY Deluxe Informant 2 Detector Kit. Instrument comes with refrigerant sensor, color-coded sensor tip, protective rubber boot, MagLite®, instruction manual, 6 AA batteries, 5 filters, custom soft carrying case and one container of refrigerant check gas all packaged in a hard carrying case.
19-8041 COMBUSTIBLE GAS ONLY Informant 2 Detector Kit. Instrument comes with combustible gas sensor, color-coded sensor tip, instruction manual, 4 AA batteries, 5 filters and custom soft carrying case.
19-8044 COMBUSTIBLE GAS ONLY Deluxe Informant 2 Detector Kit. Instrument comes with combustible gas sensor, color-coded sensor tip, protective rubber boot, MagLite®, instruction manual, 6 AA batteries, 5 filters and custom soft carrying case all packaged in a hard carrying case.
19-8037 Deluxe Upgrade Kit. Includes protective rubber boot, MagLite®, 2 AA batteries and a hard carrying case.
19-8047 Combustible Gas Upgrade Kit. To upgrade a refrigerant only Informant 2, to a dual sensing instrument. Includes combustible gas sensor, color-coded sensor tip and 5 filters.
19-8046 Refrigerant Upgrade Kit. To upgrade a combustible gas only Informant 2, to a dual sensing instrument. Includes refrigerant sensor, color-coded sensor tip, 5 filters and one container of refrigerant check gas.
19-0499 Replacement combustibles sensor
19-0510 Replacement refrigerant sensor
19-0509 Replacement filters (5-pack)
19-0497 Protective rubber boot
19-0496 Replacement check gas

 